Inspecting Burners - Desa IRONHAUS IKC42N Series Owner's Operation And Installation Manual

Table of Contents

Advertisement

2. The receiver continuously receives signals
from the hand-held remote to control the
room temperature. If the hand-held remote
is misplaced, obstructed or for any reason
cannot transmit to the receiver, the receiver
will shut off the fireplace. This will occur in 8
or more minutes depending upon location of
remote transmitter and strength of batteries.
Key Pad Lock Feature
This feature allows the user to lock/unlock the
keypad on the hand-held remote in the MANU
or AUTO mode to prevent inadvertent op-
eration (i.e. children operating the hand-held
remote control, etc.). The keypad is locked in
either on or off. Press the POWER and LOCK
buttons together to turn the unit on or off.
OpERATING OpTIONAL
GWMT1 - WALL MOUNTED
THERMOSTAT
WARNING: Do not con-
nect the thermostat to a power
source. Electrical shock and/or
a fire hazard will occur.
Light fireplace as instructed in Lighting In-
structions on page 28. Set wall thermostat to
desired temperature.
This thermostat has been electronically cali-
brated at the factory and requires no adjust-
ment or leveling.
Check pilot flame pattern and burner flame
patterns often.
pILOT ASSEMBLY
The pilot assembly is factory preset for the proper
flame height. Alterations may have occurred dur-
ing shipping and handling. Call a qualified service
person to readjust the pilot if necessary.
The height of thermopile must be 3/8" to 1/2"
above pilot flame as shown in Figure 50. The ther-
mocouple must be at a height of about 1/8" above
pilot flame. Flame from pilot burner must extend
beyond both thermocouple and thermopile.
If you pilot assembly does not meet these
requirements:
• turn fireplace off (see To Turn Off Gas to
Appliance, page 28)
• see Troubleshooting, page 33
30
oPeRATIoN
Continued

INSPeCTING bURNeRS

www.ironhaus.com or www.desatech.com
Upon installation, thermostat must be allowed
to stabilize at room temperature for a minimum
of 30 minutes for proper operation.
To turn fireplace off, adjust thermostat to the
lowest setting and turn gas control knob back
to PILOT. Pilot will remain lit.
IMPORTANT: To turn pilot off, turn gas control
knob on heater to the OFF position.
OpERATING OpTIONAL
BLOWER ACCESSORY
Locate blower controls by opening lower
louver panel on fireplace. Blower controls are
located on right side of switch bracket to the
left just inside louver panel.
The BK manual blower and BKT thermostat-
ically-controlled blower have an ON setting
and an OFF setting. Blower will only run when
switch is in the ON position. In the OFF posi-
tion, blower will not operate.
Note for BKT Only: If you are using BKT
blower with optional thermostat (wall mounted
or remote control) for fireplace, your fireplace
and blower will not turn on and off at the same
time. Fireplace may run for several minutes
before blower turns on. After heater modulates
to the pilot position, blower will continue to run.
Blower will shut off after firebox temperature
decreases.
Blower helps distribute heated air from fire-
place. Periodically check louvers of the firebox
and remove any dust, dirt or other obstruc-
tions that will hinder the flow of air.
Thermopile
3/8" to 1/2"
Piezo
Ignitor
Figure 50 - Pilot Assembly
Pilot Burner
1/8"
Thermocouple
121334-01A