Technical Details - Vetus BC12202A Operation Manual And Installation Instructions

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
7

Technical details

Type:
Supply voltage:
Frequency range:
Power consumption:
Nominal current at 230 Volt:
at 115 Volt:
Battery voltage, nominal:
Charging voltage
- fluid filled batteries
- gel filled batteries
- deep cycle batteries
- AGM batteries
Charging current, maximum
(± 5%):
Charging characteristic:
Number of isolated outputs:
Suitable for a battery capacity in Ah, at a charging time of 11 to 14 hours:
- fluid filled batteries
- gel filled batteries
- deep cycle batteries
- AGM batteries
Adjustable for battery type:
Protection
Mains Under voltage
Battery Over voltage
High temperature
Reverse polarity
Short Circuit
Fuse, mains
Fuse, batterry
Audible alarm
Indicators
Control
Ambient temperature,
- during use:
- during storage:
Forced air cooling,
number of fans:
Relative humidity:
Protection level:
Dimensions [mm]:
Weight:
14
090119.01
BC12202A BC12263A BC12403A BC12603A BC12803A BC24303A BC24503A BC24803A
300 W
400 W
1.2 A
1.8 A
2.4 A
3.6 A
20 A
26 A
IUoU, limited charging current, charging current, (equalise), maintenance current (float)
2
135 - 200
175 - 250
100 - 130
130 - 170
120 - 150
150 - 200
100 - 120
150 - 200
Against wrong connection plus and minus of the batteries
Glass fuse 'Time Lag (T)' (delayed) for the size of the fuses see '10 Connection Drawings'
Strip fuse 32 V, for the size of the fuses see '10 Connection Drawings'
Mains ON, Charger ON, Boost ,Battery over voltage, Over temperature,
1
1
293 x 180
293 x 180
x 95
x 95
1.5 kg
1.7 kg
Battery charger type BC12202A, BC12263A, BC12403A, BC12603A, BC12803A, BC24303A, BC24503A, BC24803A
230 Volt or 115 Volt (± 15%) internally adjustable
50 or 60 Hz (± 10%) cat. II
600 W
900 W
2.7 A
4 A
5.4 A
8 A
12 V
Boost / Float:
14.1 V / 13.4 V
14.5 V / 13.8 V
14.4 V / 14.0 V
14.3 V / 13.4 V
40 A
60 A
270 - 440
400 - 600
200 - 250
300 - 400
200 - 270
325 - 440
250 400
270 - 400
Fluid filled / Gel filled / Deep cycle / AGM
115 V I/P - < 80 V , 230 V I/P - < 180 V
> 15.5 V
Charger being at a too high temperature
Output
For battery reverse polarity warning
Output fuse blown, Rev. polarity
Mains on/off switch
- 10 ˚C to +50 ˚C
- 20 ˚C to +70 ˚C
2
2
10 to 90% condense free
IP20
305 x 246
340 x 292
x 90
x 90
3.5 kg
4.5 kg
1200 W
900 W
1500 W
5.3 A
4 A
11 A
8 A
Boost / Float:
28.2 V / 26.8 V
29.0 V / 27.6 V
28.8 V / 28.0 V
28.6 V / 26.8 V
80 A
30 A
3
550 - 800
200 - 300
350 - 500
400 - 525
150 - 200
250 - 325
440 - 550
150 - 200
300 - 400
525 - 800
175 - 270
325 - 440
2
2
340 x 292
305 x 246
340 x 292
x 90
x 90
4.5 kg
3.5 kg
2400 W
6.7 A
10.6 A
13.4 A
22 A
24 V
50 A
80 A
550 - 800
400 - 525
440 - 800
500 - 800
> 31 V
And charge
current
selector
switch
2
4
340 x 289
x 90
x 181
4.5 kg
8 kg

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents