Airwell AWSI-HGF009-H11 Service Manual

Airwell AWSI-HGF009-H11 Service Manual

Hgf / hhf series

Advertisement

AWSI-HGF009-H11
AWSI-HGF012-H11
AWSI-HGF018-H11
AWSI-HGF024-H11
REFRIGERANT
SM HGFHHF 1-A.1 GB
Version:2
HGF / HHF Series
Indoor Units
AWSI-HHF009-H11
AWSI-HHF012-H11
AWSI-HHF018-H11
AWSI-HHF024-H11
R410A
March- 2011
Outdoor Units
AWAU-YGF009-H11
AWAU-YGF012-H11
AWAU-YGF018-H11
AWAU-YGF024-H11
HEAT PUMP

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AWSI-HGF009-H11 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Airwell AWSI-HGF009-H11

  • Page 1 HGF / HHF Series Indoor Units Outdoor Units AWSI-HGF009-H11 AWSI-HHF009-H11 AWAU-YGF009-H11 AWSI-HGF012-H11 AWSI-HHF012-H11 AWAU-YGF012-H11 AWSI-HGF018-H11 AWSI-HHF018-H11 AWAU-YGF018-H11 AWSI-HGF024-H11 AWSI-HHF024-H11 AWAU-YGF024-H11 REFRIGERANT R410A HEAT PUMP SM HGFHHF 1-A.1 GB March- 2011 Version:2...
  • Page 2 LIST OF EFFECTIVE PAGES LIST OF EFFECTIVE PAGES Note: Changes in the pages are indicated by a “Revision#” in the footer of each effected page (when none indicates no changes in the relevant page). All pages in the following list represent effected/ non effected pages divided by chapters.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Table of Contents INTRODUCTION ..........................1-1 PRODUCT DATA SHEET....................... 2-1 RATING CONDITIONS ........................3-1 OUTLINE DIMENSION ........................4-1 PERFORMANCE DATA ......................... 5-1 SOUND LEVEL CHARACTERISTICS ................... 6-1 ELECTRICAL DATA........................7-1 WIRING DIAGRAM......................... 8-1 REFRIGERATION DIAGRAMS ...................... 9-1 TUBING CONNECTIONS .......................
  • Page 4: Introduction

    HGF/HHF//YGF series is monosplit fixed speed air conditioner designed for residential buildings. The IDU HGF/HHF is a high-wall mounted type indoor with modern appearance. Following models are included: AWSI-HGF009-H11 / AWSI-HHF009-H11 // AWAU-YGF009-H11 AWSI-HGF012-H11 / AWSI-HHF012-H11 // AWAU-YGF012-H11 AWSI-HGF018-H11 / AWSI-HHF018-H11 // AWAU-YGF018-H11 AWSI-HGF024-H11 / AWSI-HHF024-H11 // AWAU-YGF024-H11 Different appearance styles are used in HGF and HHF indoors.
  • Page 5: Indoor Unit

    INTRODUCTION Indoor Unit The indoor unit is wall mounted, and can be easily fitted to many types of residential locations. It includes: • LED display • Variable speed with PG motor • Motorized flap • High efficiency filtration to ensure a best Air Quality : Advanced filtering combine mechanical, Photo-catalytic + Bi-anti bacterial and observe bad gaseous and smokes.
  • Page 6 INTRODUCTION Outdoor Unit The outdoor units can be installed as floor or wall mounted units by using a wall supporting bracket. The metal sheets are protected by anti- corrosion paint work allowing long life resistance. All outdoor units are pre-charged. For further information please refer to the Product Data Sheet, Chapter 2.
  • Page 7 INTRODUCTION Matching Table INDOOR UNITS OUTDOOR AWSI-HGF009-H11 AWSI-HGF012-H11 AWSI-HGF018-H11 AWSI-HGF024-H11 UNITS AWSI-HHF009-H11 AWSI-HHF012-H11 AWSI-HHF018-H11 AWSI-HHF024-H11 √ AWAU-YGF009-H11 √ AWAU-YGF012-H11 √ AWAU-YGF018-H11 √ AWAU-YGF022-H11 SM HGFHHF 1-A.1 GB...
  • Page 8: Product Data Sheet

    PRODUCT DATASHEET PRODUCT DATA SHEET SHEET HGF009 / HHF009 // YGF009 HGF009 / HHF009 // YGF009 Model Indoor Unit Model Indoor Unit HGF009/HHF009 HGF009/HHF009 Model Outdoor Unit YGF009 Installation Method of Pipe Flared Characteristics Units Cooling Heating Capacity (4) 2.64 2.81 Power input (4) 0.82...
  • Page 9 PRODUCT DATASHEET HGF012 / HHF012 // YGF012 Model Indoor Unit HGF012/HHF012 Model Outdoor Unit YGF012 Installation Method of Pipe Flared Characteristics Units Cooling Heating Capacity (4) 3.22 3.52 Power input (4) 1.00 0.97 EER (Cooling) or COP(Heating) (4) 3.21 3.61 Energy efficiency class 220-240 Power supply...
  • Page 10 PRODUCT DATASHEET HGF018 / HHF018 // YGF018 Model Indoor Unit HGF018/HHF018 Model Outdoor Unit YGF018 Installation Method of Pipe Flared Characteristics Units Cooling Heating Capacity (4) 5.30 5.70 Power input (4) 1.64 1.67 EER (Cooling) or COP(Heating) (4) 3.23 3.41 Energy efficiency class 220-240 Power supply...
  • Page 11 PRODUCT DATASHEET HGF024/ HHF024 // YGF024 HGF024/HHF024 Model Indoor Unit Model Outdoor Unit YGF024 Installation Method of Pipe Flared Characteristics Units Cooling Heating Capacity (4) 6.16 6.50 Power input (4) 1.90 1.90 EER (Cooling) or COP(Heating) (4) 3.24 3.42 Energy efficiency class 220-240 Power supply Rated current...
  • Page 12: Rating Conditions

    RATING CONDITIONS RATING CONDITIONS TING CONDITIONS Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units). Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units). Cooling: Cooling: Indoor: Indoor: C DB 19 C DB 19 C WB C WB Outdoor: 35...
  • Page 13: Outline Dimension

    OUTLINE DIMENSION OUTLINE DIMENSION NE DIMENSION Indoor: HGF/HHF009-012-018-024 Indoor: HGF/HHF009-012-018-024 Unit: mm Model 18-24K SM HGFHHF 1-A.1 GB...
  • Page 14 OUTLINE DIMENSION Outdoor: YGF009-012-018-024 Model 09/12 Model 18/24 SM HGFHHF 1-A.1 GB...
  • Page 15 OUTLINE DIMENSION Unit: mm Model 09-12K 18-24K SM HGFHHF 1-A.1 GB...
  • Page 16: Performance Data

    PERFORMANCE DATA & PRESSURE CURVES PERFORMANCE DATA RFORMANCE DATA HGF009 / HHF009 // YGF009 HGF009 / HHF009 // YGF009 5.1.1 5.1.1 Cooling Capacity (kW) Cooling Capacity (kW) Entering Air WB/DB ID Coil( Entering Air WB/DB ID Coil( Entering Air DB Data OD Coil( 15/21...
  • Page 17 PERFORMANCE DATA & PRESSURE CURVES 5.1.3 Heating Capacity (kW) ENTERING AIR DB ID COIL( ENTERING WB OD COIL( 1.48 0.62 1.42 0.66 1.36 0.70 1.59 0.64 1.53 0.67 1.48 0.71 1.69 0.65 1.63 0.69 1.58 0.72 2.05 0.68 1.97 0.72 1.89 0.76 2.90...
  • Page 18 PERFORMANCE DATA & PRESSURE CURVES 5.1.4.2 Heating Discharge Pressure VS.Outdoor Temp 25 DB (ºC) 20 DB (ºC) 15 DB (ºC) Outdoor Temp.( WB HGF012 / HHF012 // YGF012 5.2.1 Cooling Capacity (kW) Entering Air WB/DB ID Coil( Entering Air DB Data OD Coil( 15/21...
  • Page 19 PERFORMANCE DATA & PRESSURE CURVES LEGEND – Total Cooling Capacity, kW – Sensible Capacity, kW – Power Input, kW WB – Wet Bulb Temp., ( – Dry Bulb Temp., ( – Indoor – Outdoor 5.2.2 Heating Capacity (kW) ENTERING AIR DB ID COIL( ENTERING WB OD COIL( 1.85...
  • Page 20 PERFORMANCE DATA & PRESSURE CURVES 5.1.5 Curves 5.1.5.1 Cooling Suction Pressure VS.Outdoor Temp 14.0 15/21(WB/DB ºC) 17/24(WB/DB ºC) 13.0 19/27(WB/DB ºC) 21/29(WB/DB ºC) 12.0 23/32(WB/DB ºC) 11.0 10.0 Outdoor Temp.(DB 5.1.5.2 Heating Discharge Pressure VS.Outdoor Temp 25 DB (ºC) 20 DB (ºC) 15 DB (ºC) Outdoor Temp.( WB SM HGFHHF 1-A.1 GB...
  • Page 21 PERFORMANCE DATA & PRESSURE CURVES HGF018 / HHF018 // YGF018 5.3.1 Cooling Capacity (kW) Entering Air WB/DB ID Coil( Entering Air Data DB OD Coil( 15/21 17/24 19/27 21/29 23/32 5.40 5.70 5.88 6.02 6.14 3.56 3.75 3.91 4.02 4.10 1.26 1.27 1.27...
  • Page 22 PERFORMANCE DATA & PRESSURE CURVES 5.1.3 Heating Capacity (kW) ENTERING AIR DB ID COIL( ENTERING WB OD COIL( 2.99 1.34 2.88 1.42 2.76 1.49 3.22 1.37 3.11 1.44 2.99 1.52 3.42 1.39 3.31 1.47 3.19 1.55 4.16 1.45 3.99 1.54 3.82 1.64 5.87...
  • Page 23 PERFORMANCE DATA & PRESSURE CURVES 5.1.6.2 Heating Discharge Pressure VS.Outdoor Temp 25 DB (ºC) 20 DB (ºC) 15 DB (ºC) Outdoor Temp.( WB HGF024 / HHF024 // YGF024 5.4.1 Cooling Capacity (kW) Entering Air WB/DB ID Coil( Entering Air Data DB OD Coil( 15/21 17/24...
  • Page 24 PERFORMANCE DATA & PRESSURE CURVES LEGEND – Total Cooling Capacity, kW – Sensible Capacity, kW – Power Input, kW WB – Wet Bulb Temp., ( – Dry Bulb Temp., ( – Indoor – Outdoor 5.4.2 Heating Capacity (kW) ENTERING AIR DB ID COIL( ENTERING WB OD COIL( 3.41...
  • Page 25 PERFORMANCE DATA & PRESSURE CURVES 5.1.7 Curves 5.1.7.1 Cooling Suction Pressure VS.Outdoor Temp 14.0 15/21(WB/DB ºC) 17/24(WB/DB ºC) 13.0 19/27(WB/DB ºC) 21/29(WB/DB ºC) 12.0 23/32(WB/DB ºC) 11.0 10.0 Outdoor Temp.(DB 5.1.7.2 Heating Discharge Pressure VS.Outdoor Temp 25 DB (ºC) 20 DB (ºC) 15 DB (ºC) Outdoor Temp.( WB 5-10...
  • Page 26: Sound Level Characteristics

    SOUND LEVEL CHARACTERISTICS SOUND LEVEL CHARACTERISTICS CHARACTERISTICS Sound Pressure Level - Indoor Sound Pressure Level - Indoor Sound Pressure Level Spectrum - Indoor (Measured as Figure 1) HGF007 / HHF007 / HGF009 / HHF009 HGF007 / HHF007 / HGF009 / HHF009 Cooling Heating Noise spectrum &...
  • Page 27 SOUND LEVEL CHARACTERISTICS HGF012 / HHF012 HGF012 / HHF012 Cooling Heating Noise spectrum & NC Curves Noise spectrum & NC Curves NC65 NC65 NC60 NC60 NC55 NC55 NC50 NC50 NC45 NC45 NC40 NC40 NC35 NC35 NC30 NC30 NC25 NC25 NC20 NC20 NC15 NC15...
  • Page 28 SOUND LEVEL CHARACTERISTICS HGF024 / HHF024 HGF024 / HHF024 Cooling Heating Noise spectrum & NC Curves Noise spectrum & NC Curves NC65 NC65 NC60 NC60 NC55 NC55 NC50 NC50 NC45 NC45 NC40 NC40 NC35 NC35 NC30 NC30 NC25 NC25 NC20 NC20 NC15 NC15...
  • Page 29 SOUND LEVEL CHARACTERISTICS Sound Pressure Level - Outdoor Sound Pressure Level Spectrum - Outdoor (Measured as Figure YGF007 YGF007 Cooling Heating Noise spectrum & NC Curves Noise spectrum & NC Curves NC65 NC65 NC60 NC60 NC55 NC55 NC50 NC50 NC45 NC45 NC40 NC40...
  • Page 30 SOUND LEVEL CHARACTERISTICS YGF009 YGF009 Cooling Heating Noise spectrum & NC Curves Noise spectrum & NC Curves NC65 NC65 NC60 NC60 NC55 NC55 NC50 NC50 NC45 NC45 NC40 NC40 NC35 NC35 NC30 NC30 NC25 NC25 NC20 NC20 NC15 NC15 500 1000 2000 4000 8000 500 1000 2000 4000 8000 Octave Band Center Frequencies [Hz] Octave Band Center Frequencies [Hz]...
  • Page 31 SOUND LEVEL CHARACTERISTICS YGF018 YGF018 Cooling Heating Noise spectrum & NC Curves Noise spectrum & NC Curves NC65 NC65 NC60 NC60 NC55 NC55 NC50 NC50 NC45 NC45 NC40 NC40 NC35 NC35 NC30 NC30 NC25 NC25 NC20 NC20 NC15 NC15 500 1000 2000 4000 8000 500 1000 2000 4000 8000 Octave Band Center Frequencies [Hz] Octave Band Center Frequencies [Hz]...
  • Page 32: Electrical Data

    ELECTRICAL DATA ELECTRICAL DATA MODEL YGF009 YGF012 YGF018 YGF024 To indoor Power Supply 1PH-220-240V-50Hz Max Current, A 5.1A 6.3A 11.1A 11.7 Circuit Breaker, A Power Supply 3x1.0 3x2.5 No. X Cross Section mm Interconnecting Cable 3X1.0+2X0.75 5x2.5 No. X Cross Section mm NOTE Power wiring cord should comply with local laws and electrical regulations requirements.
  • Page 33: Wiring Diagram

    WIRING DIAGRAM WIRING DIAGRAM HGF009 / HHF009 // YGF009 SM HGFHHF 1-A.1 GB...
  • Page 34 WIRING DIAGRAM HGF012 / HGF012 // YGF012 SM HGFHHF 1-A.1 GB...
  • Page 35 WIRING DIAGRAM HGF018 / HHF018 // YGF018 SM HGFHHF 1-A.1 GB...
  • Page 36 WIRING DIAGRAM HGF024 / HHF024 // YGF024 SM HGFHHF 1-A.1 GB...
  • Page 37: Refrigeration Diagrams

    REFRIGERATION DIAGRAMS REFRIGERATION DIAGRAMS SM HGFHHF 1-A.1 GB...
  • Page 38: Tubing Connections

    TUBING CONNECTIONS TUBING CONNECTIONS When the outdoor unit is installed above the indoor unit an oil trap is required every 5m along the suction line at the lowest point of the riser. In case the indoor unit is installed above the outdoor, no trap is required.
  • Page 39: Control System

    CONTROL SYSTEM CONTROL SYSTEM 11.1 Electronic Control 11.1.1 Abbreviations -Alternate Current - Air-Conditioner - ON or OFF status COMP - Compressor - Central Processing Unit E2PROM, EEP - Erase Enable Programmable Read Only Memory - Hardware - Indoor Coil Temperature sensor IF, IFAN - Indoor Fan - Infra Red...
  • Page 40: Compressor Operation

    CONTROL SYSTEM 11.1.2 System Operation Concept 11.1.3 Compressor operation For each Mode including POWER OFF & SB, a Min time delay of 3 min before COMP restarting except during outdoor deicing. Whenever COMP starts, it will not stop in 6 min even the RAT is changed. * For the units with memory function, the 1 time of Power ON, there will be no 3 min delay if the previous stage of unit is OFF.
  • Page 41: Fan Mode

    CONTROL SYSTEM 11.1.5.1 OFAN Speed Type The OFAN motor is a one speed AC motor and controlled by the relay on outdoor controller. 11.1.5.2 General rules 1. The OFAN is ON when COMP ON during Cool, Dry and Heat Mode. 2.
  • Page 42: Dry Mode

    CONTROL SYSTEM IFAN speed depends on the indoor coil temperature Anti-cold air function When starting the heating mode, anti-cold air function will be activated and IFAN can run at low speed or stop running. This function will terminate after the unit runs for 2min or the ICT reaches 40 degree.
  • Page 43 CONTROL SYSTEM off, the air deflector will stay in position 0. The swing is available only when the swing function is set and the indoor fan is running. The louver swing can also be set between L and B, between A and C, between B and D. 11.8 Protections 11.8.1...
  • Page 44 CONTROL SYSTEM The minimum operating time of heating mode before deicing: a) 40 min after 1 time of power on b) 5 min after system is STBY by RC or temperature condition. 11.8.4.2 Deicing Protection Procedure 1. Start to defrost: COMP stops and starts up 55S later 2....
  • Page 45: Characteristics Of Sensor

    CONTROL SYSTEM 11.10 Characteristics of sensor 11.10.1 RAT/OAT RAT/OAT R-T chart Temperature(C) 11.10.2 ICT/OCT ICT/OCT R-T Chart Temperature(C) 11-7 SM HGFHHF 1-A.1 GB...
  • Page 46 CONTROL SYSTEM 11.10.3 CTT R-T Chart Temperature(C) 11-8 SM HGFHHF 1-A.1 GB...
  • Page 47: Troubleshooting

    TROUBLESHOOTING TROUBLESHOOTING 12.1 ELECTRICAL & CONTROL TROUBLESHOOTING 12.1.1 Precautions before Performing Inspection or Repair Be cautious during installation and maintenance. Do operation following the regulations to avoid electric shock and casualty or even death due to drop from high attitude. * Static maintenance is the maintenance during de-energization of the air conditioner.
  • Page 48 TROUBLESHOOTING 12.1.3 Judgment by Indoor/Outdoor Unit Diagnostics If the malfunction still exists 4min later after stop of unit due to compressor protection, error code will be directly displayed though indoor display. In other situations, error code can be displayed by pressing LIGHT button 6 times within 4s.
  • Page 49: Exploded View & Spare Part List

    EXPLODED VIEW & SPARE PART LIST EXPLODED VIEW & SPARE PART LIST 13.1 Exploded view of indoor unit: HGF009/HHF009 13-1 SM HGFHHF 1-A.1 GB...
  • Page 50 EXPLODED VIEW & SPARE PART LIST 13.2 Spare part list of indoor Unit: HGF009 Part Code Part Description 22202135 Rear Case assy 26112201 Motor Press Plate 26152022 Bearing cushion rubber base 10352034 Cross Flow Fan 26112202 Helicoid tongue 10542704 Axile Bush 10582070 Crank 1521210801...
  • Page 51 EXPLODED VIEW & SPARE PART LIST 13.3 Spare part list of indoor Unit: HHF009 Part Code Part Description 2220213501 Rear Case assy 26112201 Motor Press Plate 26152022 Bearing cushion rubber base 10352034 Cross Flow Fan 26112202 Helicoid tongue 10542704 Axile Bush 10582070 Crank 1521210801...
  • Page 52 EXPLODED VIEW & SPARE PART LIST 13.4 Exploded view of indoor unit: HGF012/HHF012 13-4 SM HGFHHF 1-A.1 GB...
  • Page 53 EXPLODED VIEW & SPARE PART LIST 13.5 Spare part list of indoor Unit: HGF012 Part Code Part Description 01252015 Wall-Mounting Frame 2220210101 Rear Case assy 10542704 Axile Bush 10582070 Crank 10352018 Cross Flow Fan 76512051 O-Gasket sub-assy of Bearing 76512203 O-Gasket of Cross Fan Bearing 26152022 Bearing cushion rubber base...
  • Page 54 EXPLODED VIEW & SPARE PART LIST 13.6 Spare part list of indoor Unit: HHF012 Part Code Part Description 01252015 Wall-Mounting Frame 2220210101 Rear Case assy 10542704 Axile Bush 10582070 Crank 10352018 Cross Flow Fan 76512051 O-Gasket sub-assy of Bearing 76512203 O-Gasket of Cross Fan Bearing 26152022 Bearing cushion rubber base...
  • Page 55 EXPLODED VIEW & SPARE PART LIST 13.7 Exploded view of indoor unit: HGF018 13-7 SM HGFHHF 1-A.1 GB...
  • Page 56 EXPLODED VIEW & SPARE PART LIST 13.8 Spare part list of indoor Unit: HGF018 Part Code Part Description 2001246601_K46462 Front Panel Assy 1112208901 Filter Sub-assy 20012766 Front Case Sub-Assy 24252016 Screw Cover 30565127 Display Board 76712012 Water Tray Glue Plug 01002590 Evaporator Assy 10352019...
  • Page 57 EXPLODED VIEW & SPARE PART LIST 13.9 Exploded view of indoor unit: HHF018, HHF024 13-9 SM HGFHHF 1-A.1 GB...
  • Page 58 EXPLODED VIEW & SPARE PART LIST 13.10 Spare part list of indoor Unit: HHF018 Part Code Part Description 2001228601 Front Panel Assy 1112208901 Filter Sub-assy 20012288 Front Case Sub-Assy 24252016 Screw Cover 30565156 Display Board 76712012 Water Tray Glue Plug 20112081 Electric Box cover 2 10352019...
  • Page 59 EXPLODED VIEW & SPARE PART LIST 13.11 Spare part list of indoor Unit: HHF024 Part Code Part Description 2001228601 Front Panel Assy 1112208901 Filter Sub-assy 20012288 Front Case Sub-Assy 24252016 Screw Cover 30565156 Display Board 76712012 Water Tray Glue Plug 20112081 Electric Box cover 2 10352019...
  • Page 60 EXPLODED VIEW & SPARE PART LIST 13.12 Exploded view of indoor unit: HGF024 13-12 SM HGFHHF 1-A.1 GB...
  • Page 61 EXPLODED VIEW & SPARE PART LIST 13.13 Spare part list of indoor Unit: HGF024 Part Code Part Description 2001246601_K46462 Front Panel Assy 1112208901 Filter Sub-assy 12312214 Rear Case assy 24252016 Screw Cover 30565127 Display Board 01002590 Evaporator Assy 10352019 Cross Flow Fan 26152022 Bearing cushion rubber base 20012766...
  • Page 62 EXPLODED VIEW & SPARE PART LIST 13.14 Exploded view of outdoor unit: YGF009,YGF012 13-14 SM HGFHHF 1-A.1 GB...
  • Page 63 EXPLODED VIEW & SPARE PART LIST 13.15 Spare part list of outdoor Unit: YGF009 Part Code Part Description 22413007 Grille 01533029P Front panel 26233100 Small Handle 01203799P Chassis Sub-assy 01233066 Isolation Sheet 10333427 Axial Flow Fan 150130671 Fan Motor 0111347201 Condenser Assy 01703052 Motor Support Assy...
  • Page 64 EXPLODED VIEW & SPARE PART LIST 13.16 Spare part list of outdoor Unit: YGF012 Part Code Part Description 22413007 Grille 01533029P Front panel 26233100 Small Handle 01203767P Chassis Sub-assy 01233066 Isolation Sheet 10333427 Axial Flow Fan 150130676 Fan Motor 01113449 Condenser Assy 01703052 Motor Support Assy...
  • Page 65 EXPLODED VIEW & SPARE PART LIST 13.17 Exploded view of outdoor unit: YGF018 13-17 SM HGFHHF 1-A.1 GB...
  • Page 66 EXPLODED VIEW & SPARE PART LIST 13.18 Spare part list of outdoor Unit: YGF018 Part Code Part Description 26235401 Small Handle 10335257 Axial-flow Fan 15015057 Fan Motor 0170510702 Motor Support Sub-Assy 01113238 Condenser Assy 07130213 Gas Valve Assy 01255001 Top Cover 01475004 Rear grill 06813401...
  • Page 67 EXPLODED VIEW & SPARE PART LIST 13.19 Exploded view of outdoor unit: YGF024 13-19 SM HGFHHF 1-A.1 GB...
  • Page 68 EXPLODED VIEW & SPARE PART LIST 13.20 Spare part list of outdoor Unit: YGF024 Part Code Part Description 26235401 Small Handle 10335257 Axial-flow Fan 15015057 Fan Motor 0170305901 Motor Support Sub-Assy 01113396 Condenser Assy 01255001 Top Cover 0147500401 Rear Grill 02603219 Electric Box Assy 33000039...
  • Page 69: Appeddix

    APPENDIX APPEDDIX APPENDIX 14-1 SM HGFHHF 1-A.1 GB...

Table of Contents