112604 – LOLO T-Exhaust A4
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too low in comparison with
weighted average.
112605 – LOLO T-Exhaust A5
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too low in comparison with
weighted average.
112606 – LOLO T-Exhaust A6
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too low in comparison with
weighted average.
112607 – LOLO T-Exhaust A7
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too low in comparison with
weighted average.
112608 – LOLO T-Exhaust A8
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too low in comparison with
weighted average.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 163).
4. Check valve gear.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 163).
4. Check valve gear.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 163).
4. Check valve gear.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 163).
4. Check valve gear.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 163).
4. Check valve gear.
MS15026/00E 2015-05 | Troubleshooting | 67