MTU 8V4000Lx4 Operating Instructions Manual page 103

Table of Contents

Advertisement

1.4540.026 – Analog Input Low Error
Red alarm. Initiated by TecJet.
Cause
TecJet setting is not correct.
1.4540.027 – Analog Input High Error
Red alarm. Initiated by TecJet.
Cause
TecJet setting is not correct.
1.4540.028 – PWM Duty Cycle Low Error
Red alarm. Initiated by TecJet.
Cause
TecJet setting is not correct.
1.4540.029 – Battery Volt Low Error
Red alarm. Initiated by TecJet.
Cause
Supply voltage has reached
minimum limit value.
1.4540.030 – FGT Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.031 – Delta P Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.032 – FGP Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Configured limit value was not
attained.
Corrective action
u Check setting.
Corrective action
u Check setting.
Corrective action
u Check setting.
Corrective action
1. Check supply voltage.
2. Check cabling.
Corrective action
u Restart TecJet.
Corrective action
u Restart TecJet.
Corrective action
u Check position direction of TecJet.
MS15026/00E 2015-05 | Troubleshooting | 103

Advertisement

Table of Contents
loading

Table of Contents