Installation Instruction; Select The Best Location - Panasonic CS-RE9JKX-1 Service Manual

Table of Contents

Advertisement

10. Installation Instruction

10.1 Select the Best Location

10.1.1 Indoor Unit
There should not be any heat source or steam near
the unit.
There should not be any obstacles blocking the air
circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into
consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the
wall, ceiling, fence or other obstacles.
Recommended installation height for indoor unit
shall be at least 2.5m.
10.1.2 Outdoor Unit
If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation
from the condenser is not obstructed.
There should not be any animal or plant which
could be affected by hot air discharged.
Keep the spaces indicated by arrows from wall,
ceiling, fence or other obstacles.
Do not place any obstacles which may cause a
short circuit of the discharged air.
If piping length is over the rated length,
additional refrigerant should be added as shown
in the table below:
Model
Piping size
Rated
Length
Gas
Liqui
d
(m)
RE9JKX-1 9.52
6.35
7.5
(3/8")
(1/4")
RE12JKX-1 9.52
6.35
7.5
(3/8")
(1/4")
RE15JKX-1 12.7
6.35
7.5
(1/2")
(1/4")
Example: If the unit is installed at a 10m distance,
the quantity of additional refrigerant should be 50 g.
...... (10-7.5) m x 20g/m = 50 g
Max
Min
Max
Addition
Elevatio
Piping
Piping
al
n (m)
Length
Length
Refriger
(m)
(m)
ant
(g/m)
5
3
15
20
5
3
15
20
5
3
15
20
11.1.3 Indoor/Outdoor Unit
*This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
21