LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information, col-
umn 1.
2. Make sure equipment shutoff valve is fully
open.
3. Press in and turn control knob clockwise
to the OFF position.
4. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow "B"
in the safety information, column 1. If you
don't smell gas, go to the next step.
5. Turn control knob counterclockwise
to the PILOT position and press
in. Keep control knob pressed in for five
(5) seconds.
Note: You may be running this log set
for the first time after hooking up to gas
supply. If so, the control knob may need
to be pressed in for 30 seconds or more.
This will allow air to bleed from the gas
system.
• If control knob does not pop up when
released, contact a qualified service
person or gas supplier for repairs.
6. With control knob pressed in, push down
and release ignitor button. This will light
pilot. Visually locate the pilot on the control
valve cover by the edge of the burner pan
to look for flame. If needed, keep pressing
ignitor button until pilot lights.
Note: If the pilot will not stay lit after
several tries, turn the gas control knob to
OFF and call your service technician or
gas supplier.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 3
through 7.
8. Turn control knob counterclockwise
to the ON position. Burner should light.
If burner does not light, call a qualified
service person.
9. To leave pilot lit and shut off burners only,
turn control knob clockwise
PILOT position.
901268-01H
OPERATION
Continued
Ignitor
Figure 15 - Ignitor and Control Knob
Pilot
Burner
Figure 16 - Thermocouple and Pilot
1. Turn control knob clockwise
PILOT position.
2. Press in and turn control clockwise
to the OFF position.
3. Close equipment shutoff valve (see Figure
5, page 7).
During 2-3 hour appliance break-in period,
you may detect an odor from the appliance
as various paints and compounds used in
manufacturing of this log set cure. This is a
normal and temporary situation that is not
cause for alarm. However, you may want to
provide extra ventilation to the room during
this time.
To ensure proper curing of logs:
• Ignite a 2" flame and maintain it for 1
hour.
• Burn logs in consecutive 1 hour periods
raising flame an additional 2" to full flame
height for a total of three hours.
to the
www.desatech.com
Control Knob
Pilot
ON
FROM "PILOT" POSITION
SLIGHT PUSH TO
On
TO TURN OFF GAS
TO APPLIANCE
CURING
LOGS
OFF
Off
TURN OFF
PULL PUSH
Thermocouple
to the