10.0 DATA STREAMING

Data streaming provides flexibility in the retention of information captured by
the thermometer. It can be used in two separate ways: serially or wireless.

10.1 Serial Communications

To capture information from the Wahl DHS520 to a laptop/PC/Pocket PC,
DA-LOG Datalogger Software must be used.
Note
The 'Bluetooth' option must be disabled prior to using wired serial
communications from a Wahl DHS520B thermometer variant.
1)
Switch off Bluetooth communication (Wahl DHS520B variants only).
2)
Ensure that the datalogging software has been loaded to the PC/laptop
or Pocket PC as required.
3)
From the Wahl DHS520/520B, connect the serial cable to the
PC/laptop, or the Pocket PC as required.
4)
Select the required Trigger Mode on the Wahl DHS520/520B.
5)
Press the trigger to capture and stream data, release the trigger to stop.
Note
To prolong battery life, always disconnect the serial
communications cable when not in use.