SMART RECOVERY:
• On or Off, (default=On)
Applies to programmable operation only. Will start recovery 90
minutes prior to schedule change in both heating and cooling
mode.
ENGLISH/METRIC DISPLAY:
• °F or °C, (default = °F)
RESET FACTORY DEFAULTS:
Program Schedule:
• Yes/No to reset back to Energy Star default Time and Temp
schedules.
User Settings:
• Yes/No to reset the user settings in the Advanced Setup to
factory default settings.
Install Settings:
• Yes/No to reset install settings in Install/Service menus to
factory default settings.
Last 10 Faults:
• Yes/No to reset last 10 faults under Service Info menu.
Setup = FURNACE:
Upon a first time start-up of the Infinity Zone Control™, the
furnace DIP switch settings will be copied to the furnace setup
menu. Any changes can then be made from the Infinity Zone
Control™.
AIRFLOW:
• COMFORT (default)
• EFFICIENCY
Selects the airflow of the furnace when heating. EFFICIENCY is
the airflow used to meet specified ratings, COMFORT is a
decreased airflow used to increase the output air temperature and
provide increased comfort.
AC AIRFLOW:
• EFFICIENCY
• COMFORT (default)
• MAXIMUM
Selects the airflow of the furnace when cooling. COMFORT is a
decreased airflow used to improve humidity control. EFFI-
CIENCY is the airflow used to meet specified ratings. MAXI-
MUM is a fixed airflow of 400 CFM/ton based on the outdoor unit
size.
DEHUM AIRFLOW:
• NORMAL (default)
• HIGH
NORMAL airflow adjustment is used during dehumidifying. If
duct sweating is an issue, selecting HIGH will increase the
dehumidifying airflow and reduce the sweating.
LOW HEAT RISE:
• ON
• OFF (default)
Set this to ON if the system contains a bypass humidifier. The ON
setting will increase the furnace low heat airflow.
STAGING:
• SYSTEM (default)
• LOW
• HIGH
Controls the staging of the furnace. SYSTEM setting will allow
the Infinity Zone Control™ to determine furnace staging. LOW
will only run the low stage of furnace heat. HIGH will only run the
high stage of furnace heat.
OFF DELAY:
• 90 seconds
• 120 seconds (default)
• 150 seconds
• 180 seconds
Amount of time the blower will continue to run after heating has
shut off.
LOCKOUT TEMP:
• NONE (default)
• +5 to 55 deg F
Appears on dual fuel systems only (furnace with heat pump).
Outside temperature above which the furnace will NOT run.
Setup = FAN COIL:
HP/AC AIRFLOW:
• EFFICIENCY
• COMFORT (default)
• MAXIMUM
Selects the airflow of the fan coil when heating or cooling with a
heat pump (or cooling with an AC unit). COMFORT is a
decreased airflow used to improve humidity control. EFFI-
CIENCY is the airflow used to meet specified ratings. MAXI-
MUM is a fixed airflow speed of 400 CFM/ton based on the
outdoor unit size.
DEHUM AIRFLOW:
• NORMAL (default)
• HIGH
Normal airflow adjustment used during dehumidifying. If duct
sweating is an issue, selecting HIGH will increase the dehumidi-
fying airflow speed and reduce the sweating.
HEATER SIZE:
• (choices dependent upon fan coil model)
This will show the heater size entered during the start-up process.
This value can be changed to another value (limited by the model
number of the fan coil). If the electric heater is self-identifying,
this value is not shown.
Setup = HEAT PUMP / AC:
COOLING LOCKOUT:
• NONE (default)
• 45° F.
• 50° F.
• 55° F.
Outside temperature below which cooling will not be provided.
ENTERED SIZE:
• (dependent on indoor unit model)
Size of the outdoor unit entered during the start-up process. If the
outdoor unit is a communicating model, this value will not be
shown. This size can be changed here but is limited to sizes that the
indoor unit can handle.
DEFROST INTERVAL:
• 30 minutes
• 60 minutes
• 90 minutes
• 120 minutes (default)
Time interval at which defrost cycles can occur on a heat pump.
9