CD RECORDER
IMPORTANT
THIS PIONEER APPARATUS CONTAINS
LASER OF CLASS ΙΙΙ b.
SERVICING OPERATION OF THE APPARATUS
S H O U L D B E D O N E B Y A S P E C I A L L Y
INSTRUTED PERSON.
LASER DIODE CHARACTERISTICS
MAXIMUM OUTPUT POWER: 23 mW
WAVELENGTH: 778 – 787 nm

LABEL CHECK

WYXJ Type
CD RECORDER
Additional Laser Caution
1. Laser Interlock Mechanism
The position of the switch (S101) on the LOAB Assy for
detecting loading state is detected by the system
microprocessor, and the design prevents laser diode
oscillation when the switch (S101) is not on TRAY terminal
side (TRAY signal is OFF or high level.). Thus, the
interlock will no longer function if the switch (S101) is
deliberately set to TRAY terminal side (low level).
The interlock also does not function in the test mode
Laser diode oscillation will continue, if pin 1 of CN101 on
the CD-R CORE ASSY is connected to low level.
2. When the cover is opened with the servo mechanism
block removed and turned over, close viewing of the
objective lens with the naked eye will cause exposure to a
Class 3 laser beam.
Refer to page 64.
WVXJ Type
KUXJ/CA Type
Printed on Rear Panel
.
CD PLAYER
IMPORTANT
THIS PIONEER APPARATUS CONTAINS
LASER OF CLASS 1.
SERVICING OPERATION OF THE APPARATUS
S H O U L D B E D O N E B Y A S P E C I A L L Y
INSTRUCTED PERSON.
LASER DIODE CHARACTERISTICS
MAXIMUM OUTPUT POWER: 5 mW
WAVELENGTH: 760 - 800 nm
WYXJ Type
ADVARSEL
USYNLIG LASERSTRÅLING VED ÅBNING NÅR SIKKERHED SAF-
BRYDERE ER UDE AF FUNKTION.
UNDGÅ UDSÆTTELSE FOR STRÅLING
VORSICHT!
UNSICHTBARE LASER-STRAHLUNG TRITT AUS, WENN DECKEL
(ODER KLAPPE) GEÖFFNET IST! NICHT DEM STRAHL AUSSETZEN!
WYXJ and WVXJ Types
Printed on Rear Panel
CD PLAYER
Additional Laser Caution
1. Laser Interlock Mechanism
The position of the switch (S101) on the SELECT UNIT for
detecting clamping state is detected by the system
microprocessor, and the design prevents laser diode
oscillation when the switch (S101) is not on CLMP
terminal side (CLMP signal is OFF or high level.). Thus,
the interlock will no longer function if the switch (S101) is
deliberately set to CLMP terminal side (low level).
The interlock also does not function in the test mode
Laser diode oscillation will continue, if pin 9 of TA2150FN
(IC1101) on the 3CD ASSY is connected to GND, or pin 26
is connected to low level (ON), or else the terminals of
Q1101 are shorted to each other (fault condition).
2. When the cover is opened with the servo mechanism
block removed and turned over, close viewing of the
objective lens with the naked eye will cause exposure to a
Class 1 laser beam.