Panasonic WH-SXC16F9E8 Service Manual page 118

Hide thumbs Also See for WH-SXC16F9E8:
Table of Contents

Advertisement

16.5.26
Indoor Water Inlet Temperature Sensor Abnormality (F37)
Malfunction Decision Conditions:
During startup and operation of cooling and heating, the temperatures detected by the indoor water inlet
temperature sensor are used to determine sensor error.
Malfunction Caused:
1
Faulty connector connection.
2
Faulty sensor.
3
Faulty indoor unit PCB (main).
Abnormality Judgment:
Continue for 5 seconds.
118

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wh-ux16fe8

Table of Contents