1.4540.026 – Analog Input Low Error
Red alarm. Initiated by TecJet.
Cause
TecJet setting is not correct.
1.4540.027 – Analog Input High Error
Red alarm. Initiated by TecJet.
Cause
TecJet setting is not correct.
1.4540.028 – PWM Duty Cycle Low Error
Red alarm. Initiated by TecJet.
Cause
TecJet setting is not correct.
1.4540.029 – Battery Volt Low Error
Red alarm. Initiated by TecJet.
Cause
Supply voltage has reached
minimum limit value.
1.4540.030 – FGT Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.031 – Delta P Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.032 – FGP Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Configured limit value was not
attained.
86 | Troubleshooting | MS150103/01E 2015-03
Corrective action
u Check setting.
Corrective action
u Check setting.
Corrective action
u Check setting.
Corrective action
1. Check supply voltage.
2. Check cabling.
Corrective action
u Restart TecJet.
Corrective action
u Restart TecJet.
Corrective action
u Check position direction of TecJet.