Version Information; If Con Self Diagnostic Function - Sony DVP-NS15 Service Manual

Hide thumbs Also See for DVP-NS15:
Table of Contents

Advertisement

(4)
The Emergency history display screen will be restored soon.
Emg. History Check
Laser Hours
CD
999h
DVD
999h
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next] Next Page [Prev] Prev Page
(12) Press - key, return to TOP MENU.

6-4. VERSION INFORMATION

Information of firmware version.
In standby mode, press [TOP MENU], [CLEAR], [POWER] to
(1)
enter Remocon Diagnosis Mode.
(2)
Select "4. Version Information".
Version information
Firm (Main) : Ver. xxxxx
Firm (Sub)
: xxxxx
RISC
: xxxxx
8032
: xxxxx
Audio DSP
: xxxxx
Servo DSP
: xxxxx
- Return to Top Menu
(3)
Press - key, return to TOP MENU.
59min
59min
DVP-NS15/NS51P/NS43P/NS53P/K56P
6-5.

IF CON SELF DIAGNOSTIC FUNCTION

1.
IF-144/IF-145 BOARDS (IF CON) TEXT MODE
The IF-144/IF-145 boards (IF CON) test mode is the IF CON
self-diagnosis mode. The IF CON can diagnose the functions of the
IF-144/IF-145 boards that the IF CON controls. Normally, the
IF CON makes a serial communication with the SYSTEM CONTROL
and operates following the commands from the SYSTEM CONTROL,
but in the Test mode, the IF CON operates independently from the
SYSTEM CONTROL.
In the test mode, the following functions can be checked.
1. Button function
2. Remote commander receiving function
3. SYSTEM CONTROL-IF CON serial communication
4. Fluorescent display tube lighting check
- Grid check
- Anode check
5. LED control function
In the test mode, the main unit operates same as usual, except voltage
monitoring, communication, display of fluorescent display tube, and
LED control.
1. The routine that monitors +3.3V (PCONT) of MV-47/MV-48
boards is not provided.
2. The monitoring timer for serial communication with the SYSTEM
CONTROL is not provided. The main unit is not placed in the
Standby mode, even if the communication with SYSTEM
CONTROL is normal.
3. Display of fluorescent display tube.
(Normally, display is mode following the commands from
SYSTEM CONTROL).
4. LED control.
(Normally, control is mode made following the commands from
SYSTEM CONTROL).
2.
OPERATION OF SELF CHECK MODE
The Self Check mode is the function to conduct the basic test to the FL
display and DVD panel section.
2-1.
Self Check Mode Transition Processing
At the AC Power ON after reset of IF CON is released, while pressing
with the MV-47/MV-48 boards are not connected to the IF-144/
IF-145 boards, or while pressing the
IF CON in STANDBY mode, enter [RETURN] t [DISPLAY] (or
[SETUP]) on the remote commander, and the main unit transits to the
Self Check Mode.
6-3
key on the main unit with the
x

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvp-ns53pDvp-ns43pDvp-ns51pDvp-k56p