Version Information; Video Level Adjustment - Sony DVP-CX860 Service Manual

Hide thumbs Also See for DVP-CX860:
Table of Contents

Advertisement

How to see Emergency History
3
1
1.
1: Emergency Code
2: Don't Care
These codes are used for verification of software designing.
3: Historical order 1 to 9
Emergency Codes List
10: Communication to IC201 (MB-86 board) failed.
11: Each servo for focus, tracking, and spindle is unlocked.
12: Communication to EEPROM, IC101 (MB-86 board) failed.
13: Writing of hours meter data to EEPROM, IC101 (MB-86
board) failed.
14: Communication to Servo DSP IC404 (MB-86 board) failed,
or Servo DSP is faulty.
20: Initialization of tilt servo and sled servo failed. They are not
placed in the initial position.
21: Tilt servo operation error
22: Syscon made a request to move the tilt servo to wrong posi-
tion.
23: Sled servo operation error
24: Syscon made a request to move the sled servo to wrong posi-
tion.
30: Tracking balance adjustment error
31: Tracking gain adjustment error
32: Focus balance adjustment error
33: Focus bias adjustment error
34: Focus gain adjustment error
35: Tilt servo adjustment error
36: RF equalizer adjustment error
37: RF group delay adjustment error
38: Jitter value after adaptive servo operation is too large.
40: Focus servo does not operate.
41: With a dual layer (DL) disc, focus jump failed.
50: CLV (spindle) servo does not operate.
51: Spindle does not stop.
60: With a DVD disc, Syscon made a request to seek nonexistent
address.
61: With a CD disc, Syscon made a request to seek nonexistent
address.
62: With a CD disc, Syscon made a request to seek nonexistent
track No. and index No.
63: With a DVD disc, seeking of target address failed.
64: With a CD disc, seeking of target address failed.
65: With a CD disc, seeking of target index failed.
70: With a DVD disc, physical information data could not be read.
71: With a CD disc, TOC data could not be read.
80: Disc type judgment failed.
81: As disc type judgment failed, retry was repeated.
82: As disc type judgment failed, a measurement error occurred.
83: Disc type could not be judged within the specified time.
84: Illegal command code was received from Syscon.
85: Illegal command was received from Syscon.
2
2
6-12

6-8. VERSION INFORMATION

## Version Information ##
IF con.
Ver. x. xxx (xxxx)
Group
00
SYScon.
Ver. x. xxx (xxxx)
Model
xx
Region
0x
Servo DSP. Ver. 1. xxxx
Exit: RETURN
On the Test Mode Menu screen, selecting
version and region code.
The parenthesized hexadecimal number in version field is
checksum value of ROM.

6-9. VIDEO LEVEL ADJUSTMENT

On the Test Mode Menu screen, selecting
for video level adjustment. During display of color bars, OSD dis-
appears but the menu screen will be restored if pressing any key.
Measurement point
: LINE OUT VIDEO
(75 Ω terminating resistance)
Measuring instrument : Oscilloscope
Adjustment device
: RV501 on MB-86 board
Specified value
: 1.0 ± 0.02 Vp-p
[5]
displays the ROM
[6]
displays color bars
1.0 ± 0.02 Vp-p