Operation; Maintenance; To Light The Boiler; Frost Protection - IDEAL Systemiser SE User Manual

Wamm mounted, gas fired, fanned flue condensing heating boiler
Hide thumbs Also See for Systemiser SE:
Table of Contents

Advertisement

To light the boiler

1. Check that the electricity supply to the boiler is OFF.
2. Open the controls access door .
3. Set the on/off switch (C) and CH switch (D) to OFF.
4. Switch ON the electricity supply to the boiler and check that all
external controls, e.g. programmer, room thermostat, etc., are
ON.
If a programmer is fitted, refer to the separate instructions
provided.
5. Set the on/off switch (C) to ON and CH switch (D) to the desired
position.
The boiler will first execute a self-check cycle then commence
the ignition sequence.
Note. In the normal running STANDBY mode, the left hand
display digit indicates the boiler sequence and the other 2 digits
the boiler flow temperature.
Sequence
0
1
2
3
6. Close the controls door.

Operation

WINTER CONDITIONS - i.e. CH
Set the CH switch (D) to ON.
The boiler will fire and supply heat to the radiators.
SUMMER CONDITIONS
Set the CH switch (D) to OFF.
Control of water temperature
The boiler controls the central heating radiator temperature to a
o
maximum of 82
C
To return the boiler to normal running STANDBY mode press the
RESET button.
To shut down the boiler
1. For short periods
Set the CH switch (D) to OFF.
2. For longer periods
Set the on/off switch (C) and CH switch (D) to OFF, and switch
the electricity supply to OFF.
THE LOG BOOK SHOULD BE COMPLETED AFTER
EACH SERVICE AND KEPT WITH THESE
Systemiser SE -
User's
Boiler Status
Standby - no heat request
Purge
Ignition
Burner on - CH
INSTRUCTIONS

Frost protection

This is provided automatically by the boiler control unit. If frost is
likely during an absence from home, turn the boiler off at the time
switches ONLY, leaving the mains supply switched ON.
If the boiler flow temperature falls below 7
without the boiler firing, until the temperature exceeds 10
If the flow temperature falls below 3
o
temperature exceeds 10
C.

Fault condition

If the boiler will not light initially or if a fault develops during normal
operation, the first digit and the last 2 digits of the display will flash
alternately. In this event press the RESET button and the boiler
will recommence the ignition cycle.
If the fault condition persists, turn the boiler OFF and consult your
CORGI registered installer.
Loss of system water pressure
The gauge (E) on the control panel indicates the central heating
system pressure. If the pressure is seen to fall below the original
installation pressure of 1-2 bar over a period of time then a water
leak is indicated. In this event consult your local registered installer.
DO NOT OPERATE THE BOILER IF THE PRESSURE HAS
REDUCED TO ZERO FROM THE ORIGINAL SETTING.
Escape of gas
Should a gas leak be suspected contact your local gas supplier
IMMEDIATELY.
Do NOT search for gas leaks with a naked flame.

Condensate drain

The condensate drain must NOT be modified or blocked.
Blockage caused by debris or freezing can cause automatic
shutdown of the boiler.
If freezing is suspected and the pipe run is accessible, an attempt
may be made to free the obstruction by pouring hot water over the
exposed pipe and clearing any blockage from the end of the pipe.
If this fails to remedy the problem seek advice from your local
registered installer.
Cleaning
For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains, wipe with a damp cloth and
finish off with a dry cloth.
DO NOT use abrasive cleaning materials.

Maintenance

The appliance should be serviced at least once a year by a
registered installer, local gas authority or registered service
organisation.
o
C the pump will run,
o
C.
o
C the boiler will fire until the
5

Advertisement

Table of Contents