2) How to Replace Timer Setting Panel

Timer Setting Panel
To put it back on, follow the same steps in back order
Sanden Heat Pump –– Service Technical Book
Page 18 of 48
Remove Top Panel
Press the top surface of Timer Setting
Panel to release the snaps off the fitting
on the base component
Pull up Timer Setting Panel to remove it
from the base
Take the Timer Setting Panel cable off
the PCB
Note: Remove the screw together with
the harness holder
(1 screw)
End of Steps