Appendix   1   S tatics,   I nterference   L ightning   a nd   S urge   P rotection  
This   p roduct   a dopts   T VS   p late   l ightning   p rotection   t echnology   t o   a void   d amage   c aused   b y   p ulse   s ignal   t hat   i s   b elow  
3000W,   l ike   i nstantaneous   l ighting   s troke,   s urging,   e tc.   A ccording   t o   t he   a ctual   o utdoor   s ituation,   n ecessary   p rotection  
measures   m ust   b e   t aken,   b esides   e nsuring   t he   e lectrical   s afety.  
The   d istance   b etween   s ignal   t ransmission   w ires   a nd   H igh-­‐voltage   e quipment   o r   h igh-­‐voltage   c able   i s   a t   l east   5 0m.  
!
!
Outdoor   w iring   s hould   b etter   b e   r outed   u nder   e aves   a s   m uch   a s   p ossible.  
In   t he   o pen   f ield,   w iring   s hould   b e   b uried   u nderground   i n   s ealed   s teel   p ipe,   a nd   t he   s teel-­‐pipe   s hould   b e   o ne-­‐point  
!
grounding.   O verhead   r outing   m ethod   i s   f orbidden.  
In   strong   thunderstorm   area   or   high   induction   voltage   areas   (such   as   high-­‐voltage   transformer   substation),   high  
!
power   l ightning   p rotection   a pparatus   a nd   l ightning   c onductor   a re   n ecessary   t o   b e   a dded.  
The   d esign   o f   l ightning   p rotection   a nd   g rounding   o f   t he   o utdoor   d evices   a nd   c ables   s hould   b e   c onsidered   t ogether  
!
with   the   lightning   protection   demand   of   buildings.   It   also   must   conform   to   the   related   national   standards   and  
industrial   s tandards.  
The   s ystem   s hould   b e   e quipotential   g rounded.   T he   g rounding   e quipment   m ust   c onform   t o   t he   d emands   o f   s ystem  
!
anti-­‐jamming   and   electrical   safety   both   and   it   must   not   appear   short   circuit   or   mixed   circuit   with   the   zero  
conductor   of   strong   grid.   When   the   system   is   grounded   alone,   the   resistance   should   be   no   more   than   4Ω.   The  
sectional   a rea   o f   t he   g rounding   c able   s hould   b e   n o   l ess   t han   2 5mm2.   F or   g rounding   i nstructions,   p lease   r efer   t o   t he  
Installation   M anual   o f   S peed   D ome.  
Grounding   f or   C ement   P ole/Wall   I nstallation:  
 
10225  Westmoor  Drive,  Suite  300,  Westminster,  CO  80021  |   w ww.3xlogic.com  |  (877)  3XLOGIC
 
Installation  Manual  |   V ISIX   P TZ   N etwork   C amera  
Appendix  
Figure   A -­‐1   L ightning   &   S urge   P rotection  
 