Diagnosis
Abnormality /
display
Protection control
F93
Compressor abnormal
revolution
F95
Outdoor cooling high
pressure protection
F96
Power transistor module
overheating protection
F97
Compressor
overheating protection
F98
Total running current
protection
F99
Outdoor direct current
(DC) peak detection
Abnormality
Protection
Judgement
operation
4 times happen
—
within 20 minutes
4 times happen
—
within 20 minutes
4 times happen
—
within 30 minutes
3 times happen
—
within 30 minutes
3 times happen
—
within 20 minutes
Continuous
—
happen for 7 times
Problem
Compressor abnormal
revolution
Cooling high pressure
protection
Power transistor module
overheat
Compressor overheat
Total current protection
Power transistor module
current protection
53
Check location
• Power transistor module faulty or
compressor lock
• Check refrigeration system
• Outdoor air circuit
• PCB faulty
• Outdoor air circuit (fan motor)
• Insufficient refrigerant
• Check refrigeration system
• Power source or compressor lock
• Power transistor module faulty or
compressor lock