P
I
REPARING THE
NSTALLATION
Air Conditioner and Accessories
The following accessories are supplied with the air conditioner.
Accessories in the Outdoor Unit Case
MH18VP2X / MH19VP2X / MH052FXEA2
3-wire
Power Cable
(option)
Attach Energy Label to the outdoor unit properly when installing.
MH068FXEA4 / MH080FXEA4
3-wire
Power Cable
(option)
Rubber Leg
Attach Energy Label to the outdoor unit properly when installing.
The 3-wire power cable and the 2-wire assembly cable are optional. If these cables are not
supplied, use the standard cable approved by IEC standard.
The specification for cables :
3-wire power cable for main power supply
3-wire power cable for indoor power supply
2-wire assembly cable for communication
Installing and Connecting the Outdoor Unit Drain Hose
Drain hole
8
E-
2-wire
Assembly Cable
(option)
Rubber Leg
Flare Nuts, 6.35mm
outer pipe diameter
2-wire
Assembly Cable
(option)
Flare Nuts, 6.35mm
outer pipe diameter
Use
When using the air conditioner in the heating mode, ice may
accumulate. During de-icing, the condensed water must be drained
off safely. Consequently, you must install a drain hose on the outdoor
unit, following the instructions below.
1
Insert the drain plug into the drain hole on the underside of the outdoor unit.
2
Connect the drain hose to the drain plug.
3
Ensure that the drained water runs off correctly and safely.
Drain Plug
Transmitter power
Flare Nuts, 9.52mm
outer pipe diameter
Drain Plug
Transmitter power
Flare Nuts, 9.52mm
Flare Bolt
outer pipe diameter
(Nut 1/2", Bolt 3/8" )
AWG
Cross sectional area (mm
13 or fewer
2.5 or more
16 or fewer
1.5 or more
16 or fewer
1.5 or more
Energy Label
cable
Installation Manual
Installation Manual
cable
Energy Label
2
)