Specifi Cations - Vermont Castings Encore FlexBurn 2040CE Installation And Operating Manual

Hide thumbs Also See for Encore FlexBurn 2040CE:
Table of Contents

Advertisement

Encore Model 2040CE
Nominal heat out put ........7.8 - 8.0 kW (34,000 BTU/hr)
Minimum fl ue draught ........................ 12 Pa (0.048" WG)
Mean fl ue gas temp ................................ 339° C (642° F)
Effi ciency (Space heating) with Catalyst ............... 75.9%
Effi ciency (Space heating) w/o Catalyst ................ 72.9%
Area heated ..................... Up to 167 sq. m (1800 sq. ft.)
Fuel size/type .......................457-559 mm (18-22") wood
Fuel capacity ............................................. 22 kg (50 lbs)
Flue mass gas fl ow ............................................... 6.6 g/s
CO Emissions (@ 13% O
Loading .......................................................Front and top
Chimney connector:
for 8" fl ue collar ..........................203 mm (8") diameter
for 6" fl ue collar ..........................152 mm (6") diameter
Chimney fl ue size:
for 8" fl ue collar ......................... 203 mm (8") minimum
for 6" fl ue collar ......................... 152 mm (6") minimum
Flue exit position...........................Reversible, top or rear
Primary air ..... Manually set, thermostatically maintained
Secondary air .................................Fixed, self-regulating
Ash handling system ....................... Removable ash pan
Glass panel.............................High-temperature ceramic
Weight .................................................. 215 kg (475 lbs.)
578 mm
(22 ")
470 mm
(18 ")
654 mm
(25 ")
184 mm
(7 ")
Fig. 1 Encore 2040CE dimensions.
30005552
®
Encore
Specifi cations
) ..w/Cat. 0.09% w/o Cat. 0.42
2
686 mm (27")
686 mm (27")
2040CE Non-Catalytic / Catalytic Wood Burning Stove
1
Width (leg-to-leg) ........................................685 mm (27")
Depth (leg-to-leg)........................................380 mm (15")
Height to top of fl ue collar ...........................635 mm (25")
1. This value can vary depending on how the stove is
1
operated, the type and moisture content of the fuel used,
as well as the design, construction and climatic location
of your home. Figures shown are based on nominal fuel
consumption obtained under laboratory conditions and on
average effi ciencies.
95 mm
(3 ")
44 mm
(1 ")
635 mm
(25")
Top exit
flue collar
height
Drawings Not to Scale
565 mm
127 mm
(22 ")
(5")
394 mm
(15 ")
73 mm (2 ")
603 mm
(23 ")
381 mm
(15")
3

Advertisement

Table of Contents