3.2 Battery charger does not work
a) Check if 220 v is applied to the vehicle.
b) Check whether the safety circuit breaker is on (near to the display panel
above the rear door).
3.3 Hot water heater does not work, the control lights
are not lit.
a) Check 10 amp fuse for the water supply in the display unit.
b) Check 16 amp fuse for the central electrics.
3.3.1 Hot water heater does not work, the red control indicates a fault.
a) When not working, try 2 or 3 times to start.
b) Check the tank has gas in it.
c) Check that the valve on the gas tank, main gas valve in the supply and
the quick release valve for the water boiler are all open.
d) Check that the flue is not being blocked. To avoid this, remove any
luggage on the roof rack in the area of the flue.
e) Check if the Eis-ex is switched on (may be required at temperatures of
+5° C and below)
If the function of the hot water heater can not be restored, we recommend
you contact the customer service department of the equipment
manufacturer. A customer services directory is included with the
equipment.
3.4 Fridge does not cool
3.4.1 12 v operation
a) check 10 amp fuse for the fridge in the display unit.
3.4.2 220 v operation
a) Check the safety circuit breaker is switched on.
b) Check the 220 volt plug for the fridge (at the rear side) is inserted in the
socket.
3.4.3 Gas operation
a) Check that valve is open on the gas tank, main valve in the supply and
the quick release valve for the fridge.
Translated into English by
www.westfaliaLT.info - a useful site for enthusiasts and owners of VW Westfalia LT campers
b) Check whether ice-ex is switched on (required at temperatures of + 5°C
and below).
If the function of the fridge can not be restored, we recommend you
contact the customer service department of the equipment manufacturer.
A customer services directory is included with the equipment.
3.5 Heater
3.5.1 Heating does not start, no fan noise
a) Check that second battery (leisure battery) is fully charged.
b) Check 25 Amp fuse for the additional heating.
c) Check motor current fuse in the heating control unit.
WARNING! As a replacement, use only T 1.25 A fuse. The use of other
backups in case of failure can cause damage to the control unit.
3.5.2 After it is switched on the fan runs only for around 3 minutes.
The heater does not ignite and is automatically switched off.
a) Check that second battery (leisure battery) is fully charged (start vehicle
engine and with the engine running and start heating).
b) Turn the heater off and on again (no more than twice). If heater still
does not ignite it needs to be repaired in a workshop.
3.5.3 Heating is switched off due to overheating.
Red light (B) flashes on the panel.
a) Check that the wire mesh in the air intake (behind the drivers seat) is
sufficiently clear and provides an unobstructed air intake.
3.5.4 After it is switched on the fan runs only for around 20 seconds
and is automatically switched off.
a) Check that second battery (leisure battery) is fully charged (start vehicle
engine and with the engine running and start heating).
If the function of the heating can not be restored, we recommend you
contact the customer service department of the equipment manufacturer.
A customer services directory is included with the equipment.