Sears PG8MAA Installation, Start-Up And Service Instructions Manual page 15

Single-stage deluxe induced-combustion 4-way multipoise gas furnace
Table of Contents

Advertisement

Table 5---Air
Delivery
- CFM
(with Filter)*
(Continued)
FURNACE
RETURN-AIR
SPEED
EXTERNAL
STATIC
PRESSURE
(In. W.C.)
SIZE
iNLET
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
135-16/
Bottom
or
High
2065
2000
1930
1835
1710
1590
1420
1235
1025
835
048135
Side(s)
Med - High
1790
1755
1705
1640
1550
1465
1295
1145
945
775
Med - Low
1480
1480
1480
1450
1380
1295
1160
1005
855
670
High
2445
2365
2280
2190
2085
1980
1850
1705
1520
1355
Bottom
Only
Med - High
2130
2080
2025
1960
1880
1795
1690
1550
1405
1255
Med - Low
1860
1830
1800
1755
1705
1630
1530
1415
1280
1140
Bottom,
Sides
High
....
2355
2280
2160
2065
1930
1805
1655
1465
135-22/
066135
or 1 Side & Bot-
Med-High
2120
2075
1995
1970
1905
1835
1735
1645
1515
1325
tom
Med - Low
1860
1830
1800
1755
1725
1630
1530
1415
1280
1140
High
....
2215
2130
2030
1920
1795
1675
1540
1385
1 Side Only
Med-High
2070
2015
1970
1935
1855
1765
1655
1550
1445
1265
Med - Low
1860
1830
1800
1755
1725
1630
1530
1415
1280
1140
High
2465
2430
2375
2305
2215
2110
2000
1865
1715
1530
Bottom
Only
Med - High
2115
2095
2055
2005
1940
1845
1820
1675
1525
1390
Med - Low
1800
1790
1770
1735
1695
1640
1570
1465
1345
1225
155-20/
Both Sides
Or 1
High
....
2375
2285
2185
2105
1995
1870
1720
1555
060155
Side & Bottom
Med-High
2155
2125
2075
2015
1935
1830
1780
1635
1485
1365
Med - Low
1800
1790
1770
1735
1695
1640
1570
1465
1345
1225
High
....
2260
2180
2070
1975
1865
1740
1595
1440
1 Side Only
Med - High
2140
2085
2020
1950
1850
1745
1695
1545
1415
1290
Med - Low
1800
1790
1770
1735
1695
1640
1570
1465
1345
1225
A filter is required for each return-air
inlet. Airflow performance
included
3/4-in.
(19 mm) washable
filter media such as contained
in factory-authorized
ac-
cessory filter rack. To determine
airflow performance
without this filter, assume an additional
0.1 In. W.C. available external static pressure.
--
Indicates unstable operating
conditions.
U PFLOW
DOWN FLOW
HO REZO NTAL
YES
YES
[ ......
YES
\
120°_
MIN
/\
/\
YES
120°_
YES
120°_
YES
MIN
MIN
NO
NO
NO
Fig. 14 - Duct Flanges
A02020
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pg8jaa