Sears PG8MAA Installation, Start-Up And Service Instructions Manual page 11

Single-stage deluxe induced-combustion 4-way multipoise gas furnace
Table of Contents

Advertisement

NOTE:
Side return-air
openings
can be used in UPFLOW
and
most HORIZONTAL
configurations.
Do not use side return-air
openings
in DOWNFLOW
configuration.
In upflow
position
with side return inlet(s),
leveling
legs may be
used. (See Fig. 10.) Install
field-supplied,
5/16 x 1-1/2
in. (8 x
38 ram)
(max)
corrosion-resistant
machine
bolts,
washers
and
nuts.
NOTE:
Bottom
closure
must
be used when
leveling
legs are
used. It may be necessary
to remove
and reinstall
bottom
closure
panel to install leveling
legs. To remove
bottom closure
panel, see
Item 1. in Bottom
Return Air Inlet section.
(8mm)
I 3/4'
(44mm)
(8mm)
5/16"
(44mm) 1 3/4"
(44mm)
I
3/4'_"_
1
3/4"
(44mm)
(8mm)
A89014
Fig. 10 - Leveling
Legs
Leveling
Legs (If Desired)
To install leveling
legs:
1. Position
furnace
on its back.
Locate
and drill a hole in
each bottom
corner of furnace.
(See Fig. 10.)
2. For each leg, install nut on bolt and then install
bolt and
nut in hole. (Install flat washer
if desired.)
3. Install
another
nut on other side of furnace
base. (Install
flat washer if desired.)
4. Adjust
outside
nut to provide
desired
height,
and tighten
inside nut to secure arrangement.
5. Reinstall
bottom
closure
panel if removed.
DOWNFLOW
INSTALLATION
NOTE:
For downflow
applications,
this furnace
is approved
for
use on combustible
flooring
when
any one of the following
3
accessories
are used:
Special
Base, KGASB
Cased Coil Assembly
Part No.
CNPV, CNRV, CAR,
or CAP
Coil Box Part No. KCAKC
1. Determine
application
being
installed
from Table 3.
2. Construct
hole in floor per Table 3 and Fig. 11.
3. Construct
plenum
to dimensions
specified
in Table 4 and
Fig. 11.
4. If downflow
subbase,
KGASB
is used, install as shown
in
Fig. 12. If Coil Assembly
Part No. CNPV,
CNRV, CAR,
or CAP or Coil Box Part No. KCAKC
is used,
install
as
shown
in Fig. 13.
A96283
Fig. 11 -
Floor and Plenum
Opening
Dimensions
NOTE:
It is recommended
that the perforated
supply-air
duct
flanges be completely
folded over or removed
from furnace when
installing
the furnace on a factory-supplied
cased coil or coil box.
To remove
the supply-air
duct flange,
use wide
duct pliers
or
hand seamers
to bend flange
back and forth until it breaks
off. Be
careful of sharp edges. (See Fig. 140
FURNACE
(OR COIL CASING
WHEN USED)
COMBUSTIBLE
FLOORING
\
SUBBASE
SHEET METAL
PLENUM
FLOOR
OPENING
A96285
Fig. 12 - Furnace,
Plenum,
and Subbase
Installed
on a
Combustible
Floor
11