Circuit Protections

This projector provides the following circuit protections to operate in safety. If the abnormality occurs inside the projec-
tor, it will automatically turn off by operating one of the following protection circuits.

Fuse

A fuse is located inside of the projector. When the POWER
indicator is not lightning, the fuse may be opened. Check
the fuse as following steps.
The fuse should be used with the following type;
Fuse Part No. : 323 027 2605
tYPe t10.0AH 250V FuSe
215010. LItteL
How to replace the fuse
1. Loosen the screw of the lamp cover and open the lamp
cover.
. Loosen  screws of lamp ass'y and pull out the lamp
ass'y.
3. Remove the screw-A and remove the fuse cover follow-
ing to "Mechanical Disassemblies".
4. Remove the fuse from fuse holder on the Power(Filter)
board .
to install the fuse, take reversed step in the above.
Loosen the screw and
open the lamp cover.
Loosen the  screws and pull out
the lamp ass'y.
Screw-A
-5-
Fuse
Fuse cover