Board - Sony DCR-VX2000 Service Manual

Hide thumbs Also See for DCR-VX2000:
Table of Contents

Advertisement

1-4.
COLOR ELECTRONIC VIEWFINDER
SYSTEM ADJUSTMENT
Note1: The back light (fluorescent tube) is driven by a high voltage AC
power supply. Therefore, do not touch the back light holder to
avoid electrical shock.
Note2: When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note3: As the PANEL CLOSE switch is attached to the cabinet (R), this
cabinet must be attached when performing adjustments.
If you perform the adjustments with cabinet (R) removed, set the
following data.
1) Select page: 2, address: 0E, and set data: 67.
2) Select page: 2, address: 0F, and set data: 01.
Reset the data after completing adjustment.
1) Select page: 2, address: 0E, and set data: 00.
2) Select page: 2, address: 0F, and set data: 00.
[Adjusting connector]
Most of the measuring points for adjusting the viewfinder system
are concentrated in CN007 of the VC-242 board.
Connect the Measuring Instruments via the CPC-13 jig (J-6082-
433-A).
The following table shows the Pin No. and signal name of CN007.
Pin No.
Signal Name
1
GND
2
RF MON
3
SWP
4
RF IN/LANC JACK IN
5
TDO
6
GND
7
TCK
8
TDI
9
PANEL COM
10
TMS
Table 5-1-7.
CN007
20
1
Remove the CPC cover
Fig. 5-1-17.
Pin No.
Signal Name
11
H START
12
XHD/PSIG
13
EVF VB
14
EVF VR
15
EVF VCO
16
GND
17
EVF BL –
18
EVF VG
19
LANC SIG
20
EVF BL +
1. VCO Adjustment (VC-242 board)
Set the VCO free-run frequency. If deviated, the EVF screen will be
blurred.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: NTSC: DCR-VX2000
PAL: DCR-VX2000E
Adjusting method:
Order Page Address Data
1
0
01
2
D
92
3
D
92
4
D
92
5
6
7
8
D
93
9
0
01
Note2: Refer to "Table 5-4-1. Hexadecimal-decimal Conversion Table".
5-30
Camera
Arbitrary
Pin qg of CN007 (EVF VCO)
Frequency counter
D
92, 93
f = 15734 ± 30Hz (NTSC)
f = 15625 ± 30Hz (PAL)
Procedure
01
Set the data.
Change the data and set the
VCO frequency (f) to the
specified value.
Press PAUSE button.
Read the data, and this data is
named D
.
92
Convert D
to decimal notation,
92
and obtain D
'. (Note2)
92
Calculate D
' using following
93
equations (Decimal calculation)
NTSC model:
When D
'
226
92
D
' = D
' + 29
93
92
When D
' > 226
92
D
' = 255
93
PAL model:
When D
'
29
92
D
' = D
' – 29
93
92
When D
' < 29
92
D
' = 00
93
Convert D
' to a hexadecimal
93
number, and obtain D
93
D
Set the data, and press PAUSE
93
button.
00
Set the data.
. (Note2)