20-2. Steady Shot Adjustment (2)
Subject
Pattern B
(1.5m from the front of the lens)
Measurement Point
Video output terminal
Measuring Instrument
Oscilloscope
(H period)
Adjustment Page
F
Adjustment Address
42
Pattern B
White
A4 size (297mm × 210mm)
Fig.5-1-15.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: EB, set data: 76, and press the PAUSE
button of the adjustment remote commander.
3)
Expose pattern B with the zoom TELE end.
4)
Adjust the focus.
5)
Measure the horizontal position SH1 (µ sec) of the falling edge
of the waveform. (Oscilloscope is H period)
6)
Select page: F, address: EB, set data: 8A, and press the PAUSE
button.
7)
Measure the horizontal position SH2 (µ sec) of the falling edge
of the waveform. (Oscilloscope is H period)
8)
Obtain D
' using the following equation (decimal calculation).
42
3.90
D
' =
42
SH1 – SH2
Note: YAW sensor sensitivity (SE600 or SE603 of SE-108 board) is
written only on the repair parts.
9)
Convert D
' to hexadecimal notation, and obtain D
42
off to one decimal place)
(Refer to Table 5-4-1. "Hexadecimal notation-Decimal notation
conversion table" of "5-4. Service Mode". )
10) Select page: F, address: 42, set data: D
button.
Processing after Completing Adjustments
1)
Select page: F, address: EB, set data: 80, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
3)
Check that the steady shot operation is performed normally.
Black
White
0.6
×
× 99
YAW sensor sensitivity
. (Round
42
, and press the PAUSE
42
Falling edge of
waveform when
data is "8A"
SH2 ( µ sec)
5-29
H
Falling edge of
waveform when
data is "76"
SH1–SH2
SH1 ( µ sec)
Fig. 5-1-16.