J. Correct Baffl e & Blanket Placement
WARNING
Fire Risk
Improper baffl e placement may cause:
• Overheating of fi rebox
• Overheating the chimney
Baffl e must be placed properly (see instructions)
Replace baffl e if damaged or missing.
NOTE: A missing, damaged or improperly positioned baffl e
is dangerous and may cause damage and poor effi ciency.
It will also void your warranty.
Note: This are generic drawings and may
not represent your specifi c model.
CORRECT POSITION
Ceramic Blanket
Baffle Retainer Bracket
Baffle Board
Ceramic Blanket and Baffl e Board MUST be in
contact with the back of the fi rebox and even
with each other in the front.
Figure 13.1 - Correct Baffl e and Blanket Positions
February 25, 2016
Ceramic Blanket and Baffl e Board are NOT
in contact with the back of the fi rebox.
Back of Firebox
Ceramic Blanket is bunched up at the back
of the fi rebox and NOT even with the Baffl e
Board in the front.
Figure 13.2 - Incorrect Baffl e and Blanket Positions
7044-226C
INCORRECT POSITIONS
Ceramic Blanket is NOT in contact with the
back of the fi rebox and NOT even with the
Baffl e Board in the front.
Ceramic Blanket
Baffle Board
3100-I ACC
Back of Firebox