Piping And Drainage - Panasonic CS-C12ATP5 Service Manual

Table of Contents

Advertisement

CS-C12ATP5 CU-C12ATP5 / CS-C18ATP5 CU-C18ATPT5 / CS-C24ATP5 CU-C24ATPT5 / CS-C18ATP6 CU-C18ATPT6 / CS-C24ATP6 CU-C24ATPT6
(ii) Secure the Indoor unit onto the Installation bracket with
four M8 bolts with washer.
• Engage the lower flange of the hanging bracket on the
unit with the Hooks.
• Secure the unit to the Installation bracket with four M8
bolts.
• (Refer to the diagram below)
2b. For installation on the floor.
(i) Install the Indoor unit on the floor.
• Remove the Knock-out portion with a minus screw
driver.
• Engage the slot at the back center of the unit with the
Floor mount bracket.
(Refer to diagram below)
9.2.5.
CONNECT THE CABLE TO THE
INDOOR UNIT
1. Open the control box at the bottom end of the chassis and
connect the cable through the hole.
• Ensure the color of wires of outdoor unit and the
terminal Nos are the same to the indoor' unit
respectively.
• Secure the cable onto the control board with the holder
(clamper).
2. Attach the Side panels to the both left and right side of the
chassis.
• Insert two tabs on the Side panel into two slots on the
chassis, and secure it to the chassis with the screw.
3. Fix back the Intake Grille and the Filters.
9.2.6.

PIPING AND DRAINAGE

Piping and Drainage
Connecting the pipings to the indoor unit.
(Refer to "CONNECTING THE PIPING" section)
1. For the Right Side Piping.
• Align the center of the pipings and sufficiently tighten
the flare nut with fingers.
• Finally, tighten the flare nut with torque wrench until the
wrench clicks.
When tightening the flare nut with torque wrench,
ensure the direction for tightening follows the arrow on
the wrench.
• Connect the Drain Hose insulated to the drain outlet.
Fix the Drain Hose at the holding portion of the Bracket.