9.2.5.
CONNECT THE CABLE TO THE INDOOR UNIT
1. Open the control box at the bottom end of the chassis and connect the cable through the hole.
• • • • Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
• • • • Ensure the color of wires of outdoor unit and the terminal Nos are the same to the indoor's respectively.
• • • • Secure the cable onto the control board with the holder (clamper).
• • • • Insert two tabs on the Side panel into two slots on the chassis, and secure it to the chassis with the screw.
9.2.6.
PIPING AND DRAINAGE
Piping and Drainage
• • • • Cut off the Chassis with a nipper according to the inner surface for the Pipings.
• • • • Align the center of the pipings and sufficiently tighten the flare nut with fingers.
• • • • Finally tighten the flare nut with torque wrench, ensure the direction for tightening follows the arrow on the wrench.
• • • • Wrap the tube joining areas with insulating material so that there are no gaps (if it overlaps, cut the excess material) refer
diagram in "Pipe formings, insulating and finishing".
• • • • Connect the drain hose (insulated) to the drain outlet.
CS-W12CTP CU-W12CTP5 / CS-W18CTP CU-W18CTP5 / CS-W24CTP CU-W24CTP5
49