"HOLD" MODE"

When the Analyzer mode switch is in the " HOLD"position, the step function of the scan mode is stopped. The
data being displayed is then updated at a rate of one step per second.

"WATER TEMP" MODE

When the analyzer switch is in the " WATER TEMP"position, the software will update the analyzer display con-
tinuously showing the Hydro Boostâ water outlet temperature. The data being displayed is updated at a rate of
one step per second.

TEMPERATURE SENSOR STATUS

As each temperature sensor data is displayed, a check is performed to determine if sensor has failed due to
either a shorted condition, and open condition, or sensor is out of range.

SHORTED TEMPERATURE SENSOR

When a temperature sensor has failed and it has been determined to be shorted, Analyzer display will indicate
the failure with an " S11"in the sensor data field.

OPEN TEMPERATURE SENSOR

When temperature sensor as failed and has been determined to be open, Analyzer display will indicate the fail-
ure with a " 11 11"in the sensor data field.

TEMPERATURE SENSOR IS OUT OF RANGE

when temperature sensor is found to be out of range, Analyzer display will indicate the out of range condition
with a " -- --" in the sensor data field.
1593
DATA DISPLAYED
Ice Bank Modulation Rate (in %).
Ice Bank Inlet Sensor Refrigerant Temperature (in °F).
Ice Bank Outlet Sensor Refrigerant Temperature (in °F).
Ice Bank Delta T = Temperature Differential Between Ice Bank Sensor " O"
(ice bank outlet temperature) minus " i"(ice bank inlet temperature).
Condenser Outlet Sensor Temperature (in °F).
Hydro Boostâ Water Outlet Temperature (in °F).