TEST AND MEASUREMENT
10. At the Channel box press F6 to program data.
11. Select TRIM RSSI and press ENTER.
12. Make the following calculation:
RSSI offset value (from step 8) + reading noted in step 6. Enter the result into RSSI COMP field for example: 10+ 5 = 15
.
13. Press ENTER.
14. Press ESC.
15. Measure the RSSI level again by highlighting the RSSI dBm field and press ENTER.
16. Repeat steps 6 to 15 for both LOW/BOTTOM and HIGH/TOP channels.
Issue 1
Revision 0
Figure 6.22: RSSI reading 3
Figure 6.23: RSSI reading 4
Channel
GSM
Low/Bottom
1
Mch
60
High/Top
115
Section 6
– 44 –