Power Options; Wiring Terminal Designations - Honeywell Pro 3000 Series Installation Instructions Manual

Hide thumbs Also See for Pro 3000 Series:
Table of Contents

Advertisement

Available languages

Available languages

Power options

Keep wires in this
shaded
area
TH3110D Terminal block
shown

Wiring terminal designations

W
Y
G
O
Rc
R
TH3110D
C
24 Vac common. For 2 transformer
systems, use common wire from cooling
transformer.
B
Changeover valve energized in heating
R
24 Vac power from heating transformer
Rc
24 Vac power from cooling
transformer
O
Changeover valve energized in cooling
G
Fan relay
Y
Compressor contactor
W
Heat relay
Remove factory-
installed jumper only
for two-transformer
systems.
Connect C for primary AC power
(optional if batteries are installed).
B
C
Insert batteries for primary
or backup power
Aux
Y
G
O
TH3210D
C
24 Vac common
B
Changeover valve energized in heating
R
24 Vac power
L
Sends output when set to Em. Heat
O
Changeover valve energized in cooling
G
Fan relay
Y
Compressor contactor
Aux
Auxiliary heat relay
E
Emergency heat relay
2
L
R
B
C

Hide quick links: