Electrical Adjustments - Sony Walkman MZ-MH900 Service Manual

Table of Contents

Advertisement

1. PRECAUTIONS FOR ADJUSTMENT
1. Adjustment must be done in the test mode only. After adjusting,
release the test mode. A key having no particular description
in the text, indicates a set key.
2. Use the following tools and measuring instruments.
• Digital voltmeter
• Regulated dc power supply (two sets)
• Thermometer (using the Temperature Correction)
• Laser power meter
• CD adjustment disc TDYS-1 (Part No. : 4-963-646-01)
• MD1/HiMD1 hybrid adjustment disc MDW-74/GA1
(Part No. : 4-229-747-01)
• Hi-MD3 adjustment disc HMD1GSDJ
(Part No. : 7-819-098-37) *1
• Remote commander in accessories (with LCD)
• Battery charging stand and AC adapter in accessories
• Ni-MH rechargeable battery (NH-10WM) in accessories
(full charged)
• PC application software for test mode
"TestMode_Enter_For_900_800_700_600_600D_Ver***.exe" *2
• USB cable
*1) Hi-MD3 adjustment disc (HMD1GSDJ) is consumable.
Therefore if it is used 400 times, exchange it for a new.
*2) Use the newest version every time.
Copy the whole folder of this program to your PC.
Operating system: Windows 2000, Windows XP
When using this application, the SonicStage Ver. 2.0 or 2.1 is
necessary, and install it in your PC in advance.
3. Unless specified otherwise, supply DC 1.5 V from battery
terminals (CL431: BATT+, CL432: BATT–).
2. ADJUSTMENT SEQUENCE
Adjustment must be done with the following order.
Adjustment order:
1. Entering the test mode
2. Initialize the adjustment value
3. Setting the temperature correction value
4. Power supply voltage adjustment
5. Charge function check
6. Laser power check
7. Setting the adjustment values
8. Servo Overall adjustment
9. Resume clear
10. Releasing the test mode
3. ADJUSTMENT OF THE EACH ITEM
3-1. Entering The Test Mode
Refer to the "SECTION 4. TEST MODE".
3-2. Initialize The Adjustment Value
Procedure:
1. In the test mode (Display Check mode), press the [VOL--] key
to enter the Overall adjustment mode.
2. Press the [T MARK] key and display "911 ResOK?".
3. Press the
key to display "911 Reset!" and initialize the
X
adjustment values.
4. Press the
key and back to Display Check mode.
x
SECTION 5

ELECTRICAL ADJUSTMENTS

3-3. Setting The Temperature Correction Value
Procedure:
3-4. Power Supply Voltage Adjustment
Adjustment must be done with the following order.
3-4-1. Setting
Procedure:
1. In the test mode (Display Check mode), press the [VOL+] key
to enter the Manual mode.
key twice, and press the [VOL+] key twice to
2. Press the
>
display as follows.
Display
130
Temp
3. Press the
key once to select the item number 0131 and
>
display as follows.
Display
131
###S**
adjustment value (hexadecimal)
4. Measure the ambient temperature.
5. Adjust with [VOL+]/[VOL--] keys so that the adjusted value
(hexadecimal value) becomes the ambient temperature.
(example: 25 °C = 19h)
6. Press the
key to write the adjusted value.
X
7. Press the
key four times and back to the Display Check
x
mode.
1. Enter the test mode (Display Check mode), and make sure
that the power supply voltage is 1.2 V.
2. Press the [VOL+] key to enter the Manual mode.
3. Press the [VOL+] key twice to display as follows.
Display
2
POWER
key once, press the [VOL+] key once, and press
4. Press the
>
the
key once again to display as follows.
>
Display
210
PwrAdj
5. Repeat the next procedures (3-4-2. PwrAdj Adjustments), and
adjust all contents of "table 3-4-1. PwrAdj Specifications".
MZ-NH900
Ver 1.1
17