Sony Walkman MZ-MH900 Service Manual page 20

Table of Contents

Advertisement

MZ-NH900
3-6. Laser Power Check
Procedure:
1. In the test mode (Display Check mode), press the [VOL+] key
to enter the Manual mode.
2. Open the lid and press the
optical pick-up moves to the most inward track.
3. Set the laser power meter so that the laser beam from the optical
pick-up aims at the objective lens of laser power meter at right
angle.
4. Press the [VOL--] key once to display as follows.
Display
9
DESIGN
5. Press the
key three times to select the item number 9111
>
and display as follows.
Display
111
###S**
6. Confirm that the value of laser power meter is 0.67 mW ±
21%.
7. Press the
key to select the item number 9112.
>
8. Confirm that the value of laser power meter is 0.76 mW ±
18%.
9. Press the
key to select the item number 9113.
>
10. Confirm that the value of laser power meter is 6.25 mW ±
12%.
11. Press the
key four times and back to the Display Check
x
mode.
3-7. Setting The Adjustment Values
3-7-1. Hi-MD3 setting
Preparation:
1. Perform calculation every item based on the data given by the
Hi-MD3 adjustment disc by referring to the following table.
(Round off the value in decimal place)
2. Convert the calculated value into hexadecimal number.
Note: The Hi-MD3 adjustment parameters vary depending on the disc,
and therefore use the parameters of the disc used when performing
the adjustment.
Item No.
Calculating formula (*3)
0211
Pr_nominal / 0.05
(*1)
Por / 0.05
Kr × (−100)
0212
0213
Pw_nominal / 0.05
(*2)
Ppw / 0.05
Kw × (−100)
0214
0215
Prmin / 0.05
0216
Pwmin / 0.05
*1) If the "Pr_nominal" value is indicated, use the "Pr_nominal" value
and not used "Por" value.
*2) If the "Pw_nominal" value is indicated, use the "Pw_nominal" value
and not used "Ppw" value.
*3) Round off after the decimal point.
Table 3-7-1. Hi-MD3 adjustment parameter
20
key continuously until the
.
Example of Calculation:
Item No.
Parameter
0211
Pr_nominal
2.50 mW
−0.3 %/°C
0212
Kr
0213
Pw_nominal
7.35 mW
−0.4 %/°C
0214
Kw
0215
Prmin
1.9 mW
0216
Pwmin
5.8 mW
Procedure:
1. In the test mode (Display Check mode), press the [VOL+] key
to enter the Manual mode.
key once, press the [VOL+] key once, and press
2. Press the
>
the
key once again to display as follows.
>
Display
210
DiscPr
3. Press the
key once to select the item number 0211.
>
4. Adjust with [VOL+]/[VOL--] keys so that the adjustment value
of LCD becomes calculated value.
5. Press the
key to write the adjusted value.
X
6. Press the
key to next item.
>
7. Repeat adjustment from step 4 until item number 0216.
3-7-2. Other setting
1. In the test mode (Display Check mode), press the [VOL+] key
to enter the Manual mode.
2. Press the
key five time to select the item number 0113
>
and display as follows.
Display
113
###S**
adjustment value (hexadecimal)
3. Press the [VOL+]/[VOL--] key and set the according value to
each model type and destination referring to the following
table.
4. Press the
key to write the adjusted value.
X
Destination
US
Canadian, Australian
AEP, UK, East European
E18, Hong Kong, Taiwan, Korean,
Chinese, Tourist
• Abbreviation
E18: 100V - 240V AC area in E model
Table 3-7-2. Mode Type and Destination Setting
Result
Decimal
Hexadecimal
50
32h
30
1Eh
147
93h
40
28h
38
26h
116
74h
Adjustment value
41
21
A1
25

Advertisement

Table of Contents
loading

Table of Contents