Electrical & Gas Requirements - Viking Vgcc5366bss Installation Manual

Hide thumbs Also See for Vgcc5366bss:
Table of Contents

Advertisement

Electrical & Gas Requirements
Electrical Requirements
In Massachusetts:
Check your national and local codes
manual valve must be installed in the gas
regarding this unit. This range requires
supply line to the appliance.
120VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord
IMPORTANT: Any conversion required
with grounded 3-prong plug attached to
must be performed by your dealer or a
unit. See "Electrical Connection" section for
qualified licensed plumber or gas service
grounding instructions. Must be fused
company. Please provide the service person
seperately from any other circuit.
with this manual before work begins.
WARNING
Pressure Regulator:
ELECTRICAL SHOCK
• All heavy-duty, commercial type cooking
HAZARD
To avoid the risk of electrical
shock, personal injury or death;
verify electrical power is turned off at the
breaker box and gas supply is turned off
until the range is installed and ready to
operate, installation by an authorized
installer only.
Gas Connection
• Manifold pressure should be checked with
The gas supply (service) line must be the
same size or greater than the inlet line of the
appliance. This range uses a 1/2" (1.3 cm) ID
NPT (Sch40) inlet. Sealant on all pipe joints
must be resistive to LP gas.
The range is designed specifically for
natural gas or liquid propane (LP) gas.
Before beginning installation verify that
the model is compatible with the intended
gas supply.
• The appliance must be disconnected from
Manual shut-off valve:
This installer-supplied valve must be installed
in the gas service line before the appliance
in the gas stream and in a location where it
can be reached quickly in the event of
an emergency. Any opeing behind the range
shall be sealed.
12
A "T" handle type
equipment must have a pressure regulator
on the incoming service line for safe and
efficient operation, since service pressure
may fluctuate with local demand. External
regulators are not required on this range
since a regulator is built into each unit at
the factory. Under no condition bypass
this built-in regulator.
a manometer, natural gas requires 5.0"
W.C.P. and LP gas requires 10.0" W.C.P.
Incoming line pressure upstream from the
regulator must be 1" W.C.P. higher than
the manifold pressure in order to check
the regulator. The regulator used on this
range can withstand a maximum input
pressure of 1/2" PSI (14.0" W.C.P.). If the
line pressure is in excess of that amount, a
step down regulator will be required.
the gas supply piping system during any
pressure testing of that system.
Electrical & Gas Requirements
Flexible Connections:
In Canada:
If the unit is to be installed with flexible
connectors for gas appliances and CAN
couplings and/or quick-disconnect fittings,
1-6.9 M79 quick disconnect devices for use
the installer must use a heavy-duty AGA
with gas fuel.
design-certified flexible connector of at least
1/2" (1.3 cm) ID NPT (with suitable strain
In Massachusetts:
reliefs) in compliance with ANSI Z21.41
installed with a 36" (3-foot) long flexible
and Z21.69.
gas connector.
2-3/4"
(7.0 cm)
31-1/16"
(78.9 cm)
4-3/8"
(11.1 cm)
13
CAN 1-6, 10-88 metal
This appliance must be
Gas or electrical
connection in
this area