CONNECTION OF THE POWER SUPPLY CABLE
•
Unhook the terminal board cover by inserting a screwdriver into the two hooks "A" (fig.
10.2).
•
Open the cable gland by unscrewing screw "F" (fig. 10.3), unscrew the terminal screws.
•
Insert the feeder cable of the suitable section (as described in the next chapter) into
the cable gland.
•
Connect the phase, neutral and earth cables to the terminal block according to the
diagram in figure 10.4.
•
Pull the feeder cable and block it with cable gland.
•
Close the terminal block cover (check the two hooks "A" are correctly hooked).
IMPORTANT: To connect the power supply cable DO NOT unscrew the screws fixing
the cover plate behind the terminal block.
WARNING: If the power supply cable is damaged, it must be replaced only by an
authorised service agent in order to avoid a hazard.
POWER SUPPLY
230 V~ 50 Hz
FEEDER CABLE SPECIFICATIONS
Type "H05RR-F"
230 V~
3 x 1,5 mm
3023 W
2
A
Fig. 10.2
230 V
L
N
E
F
Fig. 10.3
E
Earth
N
Neutral
L
Live
Fig. 10.4
45