CONNECTION OF THE POWER SUPPLY CABLE
Unhook the terminal board cover by inserting a screwdriver into the two hooks "A" (fig.
10.2).
Open the cable gland by unscrewing screw "F" (fig. 10.3), unscrew the terminal screws.
Insert the feeder cable of the suitable section (as described in the next chapter) into
the cable gland.
Connect the phase, neutral and earth cables to the terminal block according to the
diagram in figure 10.4.
Pull the feeder cable and block it with cable gland.
Close the terminal block cover (check the two hooks "A" are correctly hooked).
IMPORTANT: To connect the power supply cable DO NOT unscrew the screws fixing
the cover plate behind the terminal block.
WARNING: If the power supply cable is damaged, it must be replaced only by an
authorised service agent in order to avoid a hazard.
POWER SUPPLY
230 V~ 50 Hz
FEEDER CABLE SPECIFICATIONS
Type "H05RR-F"
230 V~
3 x 1,5 mm
3023 W
2
A
Fig. 10.2
230 V
L
N
E
F
Fig. 10.3
E
Earth
N
Neutral
L
Live
Fig. 10.4