PROGRAMMING THE ENTRACOMP
26SA
®
Functions of the ENTRACOMP
26SA are programmed by placing the
®
program cards on the TOUCH CARD
reader plate in a proper sequence.
®
It is helpful to think of placing a program card on the TOUCH CARD
reader plate as depressing a key on a keyboard or key pad. You may
begin programming at any time by placing the first program card of the
sequence on the TOUCH CARD
®
reader plate. At this point the LED
indicator will show an amber color. When you remove the program card
®
from the TOUCH CARD
reader plate, the LED indicator will flash the
amber color awaiting the next program card. Placement of the next
®
program card on the TOUCH CARD
reader plate causes the amber
LED to stop flashing and become solid. In like manner, the remainder
of the program cards for the programming sequence are placed on the
®
TOUCH CARD
reader plate. At the end of the programming sequence,
the LED indicator will flash green to indicate that the programming
instruction has been accepted. While programming, it is necessary
®
to place the next card of the sequence on the TOUCH CARD
reader
plate while the LED indicator is flashing amber (you have approximately
10 seconds between each card). If the amber LED times out, it will be
necessary to restart the programming sequence. Should an error be
made in the programming sequence, the LED indicator will flash red
instead of green.
VALIDATING A SINGLE CARD. To validate a single card, place the
sequence of program cards representing the card number on the
TOUCH CARD
®
reader plate and then place the "VALID" card on
®
the TOUCH CARD
reader plate.