4. Connect power and control lines to wire leads provided as
per the wiring instructions.
5. Plug connector into reader board.
6. Place ENTRACOMP
top edge first, centering housing on retaining tabs. Secure
housing to plate at bottom using one 6-32 x 3/8 security
screw provided or equivalent.
7. Lock cam lock.

SURFACE HOUSING WITH FLANGE MOUNT ADAPTER

(See Figure 7)
1. Position flange mount adapter (optional) against post flange
(not supplied). Locate and mark four (untapped) holes. Then
drill and tap four 10-32 holes in post flange.
2. Apply silicone bead around perimeter of post flange. Place
flange mount adapter against post flange and secure with
four 10-32 x 1/2 flat head countersunk screws provided.
3. Follow instructions 2 - 7 for post mount adapter.
®
26SA housing against mounting plate,