Wireless Relay Box (BDR91) to control a Zone Valve

evohome
Controller
If you are NOT
following GUIDED
CONFIGURATION
follow these steps
on your evohome
Controller display first:
1. Press and hold
"Settings"
for 3
seconds
2. Press the green tick
3. Press ADD ZONE
4. Type a name for the
new zone and press
the green tick
5. Press ZONE VALVES
!
All of the remote
room sensors will
automatically exit from
their binding menu after
a short period.
Step 3: Power up and bind devices
Power up and bind a Wireless Relay Box
(BDR91) to control a Zone Valve
Make sure the Wireless Relay Box (BDR91) is
wired to the Zone Valve and powered up.
If you want to control the zone temperature with the evohome
Controller (the evohome Controller needs to be located in that
zone) press YES, otherwise press NO and bind a sensor – either
Digital Room Thermostat (DTS92), Single Zone Thermostat
(Y87RF), or Room Temperature Sensor (HCW82/HCF82).

To bind the Digital Room Thermostat (DTS92)

Press and hold the power button
1
seconds to put the unit into standby
Press the up and down arrows together
2
for 3 seconds – it should say INst
Press the down arrow – it should say COnt
3
Press the up arrow three times – it should say CLr
4
Press the power button once to clear
5
any previous binding data
Press the up arrow – it should say COnt
6
Press the power button once to send the
7
binding signal to the evohome Controller
You should receive a SUCCESS message on the
8
evohome Controller (if not go back and re-bind)

To bind the Single Zone Thermostat (Y87RF)

Press and hold on the left touch zone (just below
1
and to the left of the display) for approximately
10 seconds until a flashing 'Bo' is displayed
Turn the dial clockwise until a flashing 'Co' is displayed
2
Press the left touch zone once to send the
3
binding signal to the evohome Controller
You should receive a SUCCESS message on the
4
evohome Controller (if not go back and re-bind)