Mixing Valve Controller (HM80) continued
!
Still want to control the
Boiler?
A Mixing Valve Controller
will not provide a heat
demand to the boiler.
If you do want this zone
to provide a heat demand
simply change the heating
type from 'MIXING VALVE'
to 'ZONE VALVES' once
the Mixing Valve controller
is bound.
There's no need to re-bind
any device – The Mixing
Valve Controller will still
operate as intended and
the evohome Controller
will send the heat demand
to the boiler.
Step 3: Power up and bind devices
To bind the Room Temperature
Sensor (HCW82 or HCF82)
Press the bind button on the bottom right hand corner
1
of the unit once. The red LED light will flash
You should receive a SUCCESS message on the
2
evohome Controller (if not go back and re-bind)
1
Then on the Mixing Valve Controller
Press and hold both buttons on the Mixing Valve
1
Controller for 4 seconds until the red light flashes
On the evohome Controller press
2
the green bind button
Press the next arrow on the evohome Controller
3
1
PRESS
AND HOLD
4 SEC