6
CONTROLS
6.2

CONTROL PANEL - GASOLINE

A
Hour Meter
Records the number of hours the engine has run.
Use the hour meter to manage a good scheduled
maintenance program (refer to the Maintenance
Guide).
B
Ignition Switch
Has four positions:
OFF - prevents all electrical functions from
operating. Switch must be in the OFF position to
remove the key.
ON - for normal operation.
START - engages the starter. Release the key after
engine starts (the switch automatically returns to
ON).
ACC. - has no function on this unit.
NOTE
If the engine fails to start, or if it "dies" for any
reason, the ignition switch must be returned to
the OFF position before restarting is attempted.
This feature prevents damage to the starter and
flywheel teeth that can occur if the starter is
engaged while the engine is running. Wait 30
seconds before restarting engine.
C
12 Volt Power Outlet
Provides a 12 volt power supply for accessories.
D
Reel Enable Switch
This switch must be in the on position (1) in order
for the reels to rotate. The switch must be in the off
position (0) for the unit to be started.
E
Working Light Switch
The Working light Switch turns the two working
lamps on and off.
en-20
JACOBSEN G-PLEX III Series: FH & FJ
SAFETY AND OPERATORS MANUAL
A
WARNING
When the ignition is switched on, if the
units are in the lowered position they will
raise. It should be ensured that
operators/bystanders are clear of all
moving parts before the ignition switch is
switched on.
F
Mow / Transport Lever
This lever limits the maximum traction speed for
cutting.
G
Throttle
Push all the way forward for normal engine operating
speed, and all the way back for idle.
H
Choke
Pull the choke control out to start the engine. In
warm weather, move the choke control slowly to the
off position. In cold weather allow the engine to run
smoothly before moving the choke control to the off
position.
J
Warning Light
b
On when the engine oil pressure is too low for
operation.
K
Joystick Unit Lift/Lower Control
The joystick can be operated in 2 directions (single
Axis) to raise and lower the cutting units.