H. Fan Kit
NOTICE: Wiring for fans must be done before framed
enclosure is cvompleted. If using a Heat Zone kit, it also
must be installed before enclosure is complete.
The SC60 is a heat circulating fireplace that comes
equipped with a fan kit, junction box, and an ON/OFF
variable speed control (wall mount type).
110 VAC service must be connected to the fan kit by a
licensed electrician. See Figure 7.5 for the typical fan kit
wiring diagram and the typical access to the junction box.

Service or Replace the Fan Kit

Remove the lower fireplace grille.
Unplug the blower from the junction box on the fireplace.
Remove the screws for the blower mounting brackets
and carefully slide blower out of the fireplace.
To reinstall the fan kit, reverse these steps.
We recommend the fan kit be installed at the time of initial
installation of the fireplace to avoid considerable recon-
struction.
WARNING! Risk of Electric Shock! DO NOT remove
grounding prong from plug or route cord under or in front
of appliance. Plug directly into a properly grounded three-
prong receptacle and route cord away from appliance.
WHT
(Silver Screw)
Ground
Blower
Receptacle
110V Supply
1. Fan
Figure 3.9
Wiring for Fan Kit
Note: If a speed control option is desired, it is recommended
that you use the BC10 Motor Speed Control Kit supplied
with the fireplace to ensure proper functioning. Refer to
the instructions packed with it for proper installation.
to 110V house
wiring
BLK
WHT
Ground
BLK
(Brass Screw)
Ground
Screw
Wall
Junction
Box
Ground
WHT
BLK
Heatilator • SC60 Installation Manual • 4013-281 • Rev F • 05/06/15
Wall
Switch
15