Heatilator SCKVP-B Installation Instructions Manual
Heatilator SCKVP-B Installation Instructions Manual

Heatilator SCKVP-B Installation Instructions Manual

Natural gas to propane conversion kit

Advertisement

Quick Links

Models:
SCKVP-B
Natural Gas to Propane
Conversion Kit
This conversion kit has been tested for use with specifi c Heatilator gas appliances. Check with your local building code
agency before you begin installation to ensure compliance with local codes, including the need for permits and follow-up
inspections. If you encounter any problems regarding code approvals, or if you need clarifi cation of any of the instructions
contained here, contact your dealer. For the dealer nearest you, please visit www.heatilator.com.
HEATILATOR® is a registered trademark of Hearth & Home Technologies Inc.
Note: Gas conversions should only be performed by a
qualifi ed service person, and/or where required by state
and local codes, licensed installer/service technician. In
the Commonwealth of Massachusetts, installation must be
performed by a licensed plumber or gas fi tter.

A. Components

Description
Burner Orifi ce
Pilot Orifi ce .014 in.
Variable Regulator 6.3 in. - 10.0 w.c.
SCKVN-B/SCKVP-B Label
Tools Required:
Phillips screwdriver
Straight screwdriver
Pliers
Non-corrosive leak-check solution
1/2, 5/8 & 7/16 wrench
Manometer
CAUTION
Sharp Edges
Wear protective gloves and safety
glasses during installation.
Part #
See Table 1
29477
230-1520
4016-129
Heatilator • SCKVP-B Conversion Kit • 4016-125 Rev D • 02/07
Note: This kit is for a one time conversion only. Discard
unused parts.
Note: An arrow (
) found in the text signifi es change in
content.
Burner Orifi ce
Model
GDST60
GDFL60
GDCR60
GDCL60
GDCH60
GBST36
GBCR36
GBCL36
GBFL36
GNTC50
CD4236R
CD4842R
ND3630
ND3933
ND4236
ND4842
NB3630
NB3933
NB4236
NB4842
Installation
Instructions
Table 1
Size
Part #
0.067
17812
0.067
17812
0.067
17812
0.067
17812
0.067
17812
0.067
17812
0.067
17812
0.067
17812
0.067
17812
0.056
13845
0.065
4021-062
0.067
4021-198
0.052
4031-163
0.055
4031-164
0.058
4031-165
0.064
4031-162
0.052
4031-163
0.055
4031-164
0.058
4031-165
0.064
4031-162
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCKVP-B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Heatilator SCKVP-B

  • Page 1 Conversion Kit This conversion kit has been tested for use with specifi c Heatilator gas appliances. Check with your local building code agency before you begin installation to ensure compliance with local codes, including the need for permits and follow-up inspections.
  • Page 2 If electricity has been brought to the appliance, shut off all power by turning off the appropriate circuit breaker or removing the fuse in the electrical panel. Figure 1.1 Valve Plate Heatilator • SCKVP-B Conversion Kit • 4016-125 Rev D • 02/07...
  • Page 3 Remove the Burner Orifi ce - Novus ND/NB Series Remove Remove Back Log Remove Back Log Burner Pan Figure 1.3 Remove Rear Log Figure 1.6 Loosen the Retaining Nut - Caliber Heatilator • SCKVP-B Conversion Kit • 4016-125 Rev D • 02/07...
  • Page 4 Loosen the Pilot Hood (CD & Designer Series) • Replace screen and glass frame assembly. • Replace control access panel. • Refer to Section 1.C. Figure 1.8 Pilot Orifi ce (CD and Designer Series) Heatilator • SCKVP-B Conversion Kit • 4016-125 Rev D • 02/07...
  • Page 5 Turn the control knob clockwise and counterclockwise to confi rm the fl ame adjusts up and down. • Let the appliance run for fi fteen minutes, allowing the fl ame to reach its height and color. Heatilator • SCKVP-B Conversion Kit • 4016-125 Rev D • 02/07...
  • Page 6 fl ame time to reach its height and color before making adjustments to the air shutter. As the air shutter is closed, the fl ame should be taller and darker. Heatilator • SCKVP-B Conversion Kit • 4016-125 Rev D • 02/07...

Table of Contents