Indoor Unit Installation

1.

Installing the mounting plate

• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring
points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting plate retention spots and dimensions
125
φ80
60
Drain hose position
2.

Boring a wall hole and installing wall embedded pipe

• For walls containing metal frame or metal board, be sure to use a wall
embedded pipe and wall cover in the feed-through hole to prevent possible
heat, electrical shock, or fire.
• Be sure to caulk the gaps around the pipes with caulking material to prevent
water leakage.
1) Bore a feed-through hole of 80mm in the wall so it has a down slope toward
the outside.
2) Insert a wall pipe into the hole.
3) Insert a wall cover into wall pipe.
4) After completing refrigerant piping, wiring, and drain piping, caulk pipe hole
gap with putty.
3.
Inter-unit wiring
1) Open the front panel, then remove the service lid.
2) Pass the inter-unit wiring from the outdoor unit through the feed-
through wall hole and then through the back of the indoor unit. Pull
them through the front side. Bend the ends of tie wires upward for
easier work in advance. (If the inter-unit wiring ends are to be
stripped first, bundle wire ends with adhesive tape.)
3) Press the bottom frame of the indoor unit with both hands to set it on
the mounting plate hooks. Make sure the wires do not catch on the
edge of the indoor unit.
■English
Recommended mounting plate retention
spots (9 spots in all)
Place a leveler on raised tab.
(Bolt size: M10)
83
413.5
44.5
1050
Through-the-wall
hole φ80mm
* The removed pipe port cover can be
kept in the mounting plate pocket.
(Bolt size: M10)
100
φ80
100
99.5
Gas pipe end
Liquid pipe end
Removed pipe
port cover
A
Mounting
plate
Wall embedded pipe
(field supply)
Wall hole cover
(field supply)
Hang indoor unit's hook here.
When stripping the
ends of inter-unit wiring
in advance, bind right
ends of wires with
insulating tape.
Use tape
measure
as shown.
Position the
end of tape
measure at ∇ .
unit: mm
Inside
Outside
Caulking
Wall embedded pipe
(field supply)
A
Mounting plate
Inter-unit wiring
8