QUICK START GUIDE
INSTALLATION
1. Plug in the power/electrical cord.
2. Gently push the unit into position. Be careful not to
entangle the cord or water and drain lines.
3. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments. The unit's top
surface should be approximately 1/8" (3 mm) below
the countertop.
4. Install the anti-tip bracket.
5. Remove interior packing material and wipe out the
inside of the unit with a clean, water-dampened cloth.

Integrated Panel Installation

1. Fully open door/drawer.
2. Starting at corner, pull
gasket away from door/
drawer.
3. Continue to pull gasket
free from gasket channel.
4. Upon removal, lay gasket down on a flat surface.
5. The panel should be aligned with the outside edge
(opposite the hinge) and high enough to align with the
highest point in the door/drawer.
Align Top Of Panel With Highest Point Of Door/Drawer
Align Panel
Against
Door/Drawer
Edge First
9
NOTICE
Due to differences in floor construction or
surrounding cabinetry, the panel may not sit
flush with the top of the door/drawer.
Panel
6. Secure integrated
panel to door/drawer
using clamps. A
robust tape may also
be used. U-Line
recommends the use
of bar clamps to
secure the panel to
the door/drawer. If
using tape, be
certain the tape will
not damage panel
finish upon removal.
7. Using a 7/64" (3 mm)
drill bit, drill 6 pilot
holes into the wood
panel 1/2" (12 mm)
deep using the holes in the door/drawer frame as a
guide.
NOTICE
It is important to ensure that all drilled holes are
drilled to the correct depth in order to avoid
splits in the wood when hardwood is installed.
8. Locate 6 of the #6x 1-1/4" (32 mm) screws provided
with your unit.