U-Line CLR1215 Quick Start Manual page 10

1000 series
Hide thumbs Also See for CLR1215:
Table of Contents

Advertisement

QUICK START GUIDE
GRAVITY DRAIN
Normal
Proper Drain
With Trap
Poor Drainage, Water Will Back Up
With Trap and Vent
Proper Drain
A gravity drain may be used if:
Drain line has at least a 1" drop per 48" (approximately
2 cm drop per 100 cm) of run.
Drain line does not create traps and is vented per local
code.
1. Cut the pre-installed drain tube to length.
2. Connect to your local plumbing per the local code.
3. If necessary, insulate drain line to prevent
condensation.
!
CAUTION
Failure to connect water supply or drain line
connections properly can result in personal
injury and property damage. Gravity drain
connections must be routed downward from the
rest of the unit at the rate of 1/4" per foot (1 cm
per 50 cm).
FACTORY INSTALLED DRAIN PUMP
If your drain line will run up to a stand pipe, disposal or
spigot assembly, or does not otherwise meet the
requirements for a gravity drain, you may have ordered a
pre-installed U-Line P60 drain pump.
If you need to install a P60 drain pump into your unit, see
DRAIN PUMP section in the User Manual.
See below for typical installations requiring a drain pump.
Stand Pipe
P60 Pump Required
Disposal Assembly
P60 Pump Required
Air Gap
(Optional Hook-Up)
7
u-line.com
Waste
Valve
Cold
Hot
Water
Water
Waste
Waste
Cold
Water
Hot
Water
Valve