RX-V1900/HTR-6290/DSP-AX1900
When checking the P.C.B.s:
•
Put the rubber sheet and the cloth over this unit. Then
place the rear unit upside down on the cloth and check
it. (Fig. 9)
•
Reconnect all cables (connectors) that have been
disconnected. Be sure to use the extension cable for
servicing for the following section.
FL (1) P.C.B. CB901–FL (2) P.C.B. CB970:
MF126500 (26P, 500mm)
FL (2) P.C.B. CB971–OPERATION (2) P.C.B. CB803:
MF115500 (15P, 500mm)
FUNCTION (1) P.C.B. CB409–POWER (3) P.C.B. CB18:
MF114400 (14P, 400mm)
FUNCTION (1) P.C.B. CB406–POWER (4) P.C.B. W1:
MF408250 (8P, 250mm)
•
When connecting the flexible flat cable, be careful
with polarity.
•
Connect the ground point of the rear unit to the chas-
sis with a ground lead or the like. (Fig. 9)
NET P.C.B. (R, T, K, A, B, G, E, L, J models)
CONNECT (2) P.C.B. (U, C models)
CB971
24
CB409
MF126500
CB970
MF114400
MF408250
MF115500
CB901
P.C.B. をチェックする場合には:
・ 本機の上にゴムシートと布を敷き、その上にリアユ
ニットを裏返しに置いてチェックします。 (Fig. 9)
・ 外したケーブル(コネクター)をすべて接続します。
ただし次の区間は、サービス用延長ケーブルを使用
してください。
FL(1)P.C.B. CB901 − FL(2)P.C.B. CB970:
MF126500(26P、500mm)
FL(2)P.C.B. CB971 − OPERATION(2)P.C.B. CB803:
MF115500(15P、500mm)
FUNCTION(1)P.C.B. CB409 − POWER(3)P.C.B. CB18:
MF114400(14P、400mm)
FUNCTION(1)P.C.B. CB406 − POWER(4)P.C.B. W1:
MF408250(8P、250mm)
・ フラットケーブルを接続する際、極性に注意してく
ださい。
・ リアユニットのアースをアース線等でシャーシに接
続してください。 (Fig. 9)
FUNCTION (1) P.C.B.
DSP P.C.B.
CB406
Rubber sheet and cloth
ゴムシートと布
CB803
Fig. 9
Rear unit
リアユニッ ト
Ground lead
アース線
Shassis
シャーシ