Facing Requirements
•
Attach the included fiber board (or other non-combustible) the the fireplace and framing (see
Figure 25 below). This non-combustible facing must extend from the base of the fireplace to
the header and to the framing members on both sides.
Attach the included non-combustible fiber
board to the fireplace and framing as
shown.
Use screws to secure the fiber
board to the fireplace.
Fiber Board (or other non-combustible) is
required from the glass frame edge to the
side framing (6-1/2").
© Travis Industries
Installation
(for qualified installers only)
Drywall
Fiber
Board
4090807
WARNING: Do not use adhesive to
secure the cement board or facing. The
high temperatures of the fireplace may
cause adhesives to emit odors. Use
mastic or thin set (or other non-
combustible, non-odorous adherent) to
attach the facing to the cement board.
Flanges are provided on the fireplace
for the screws to attach to.
Figure 25