138
Fault
Starter or living area bat-
tery is not charged when
operated in 240 V mode
Living area battery is not
charged during vehicle
operation
12 V indicator lamp does
not light up
12 V power supply does
not work
12 V power supply does
not work in 240 V opera-
tion
Cause
Jumbo flat fuse (50 A) in
the starter or living area
battery is defective
Charger module in the
transformer/rectifier is
defective
Fuse on terminal D+ of
the alternator is defective
Disconnector relay in the
transformer/rectifier is
defective
12 V power supply
switched off
Battery cut-off switch on
the transformer/rectifier is
switched off
Starter or living area bat-
tery is not charged
Disconnector relay in the
transformer/rectifier is
defective
Flat fuse (2 A) in the liv-
ing area battery is defec-
tive
12 V power supply
switched off
Battery cut-off switch on
the transformer/rectifier is
switched off
The living area battery is
discharged
Jumbo flat fuse (40 A) in
the living area battery is
defective
Disconnector relay in the
transformer/rectifier is
defective
12 V power supply
switched off
Battery cut-off switch on
the transformer/rectifier is
switched off
Charger module in the
transformer/rectifier is
defective
240 V automatic circuit
breaker has triggered
Jumbo flat fuse (40 A) in
the living area battery is
defective
Remedy
Replace jumbo flat fuse
(50 A) in the starter or liv-
ing area battery
Contact customer service
Replace fuse
Contact customer service
Switch 12 V power sup-
ply on
Set battery cut-off switch
to on
Charge the starter or liv-
ing area battery
Contact customer service
Replace flat fuse (2 A) in
the living area battery
Switch 12 V power sup-
ply on
Set battery cut-off switch
to on
Charge the living area
battery
Replace jumbo flat fuse
(40 A) in the living area
battery
Contact customer service
Switch 12 V power sup-
ply on
Set battery cut-off switch
to on
Contact customer service
Contact customer service
Replace jumbo flat fuse
(40 A) in the living area
battery