Back At Base Station - Completing The Perimeter Wire Setup - Robomow RL2000 Operating & Safety Manual

Robotic
Hide thumbs Also See for RL2000:
Table of Contents

Advertisement

Robomow RL555, RL855, RL2000
P Insert the pegs at distances that will keep the wire down below the grass
level and prevent the wire from becoming a tripping hazard
P The wire and the pegs will soon become invisible under the growth of
new grass.
P If additional wire is required in order to complete the setup, connect it
using the water-proof wire connectors supplied with Robomow. (Refer to
paragraph 10.7 – Splicing the Perimeter Wire).
c IMPORTANT c
Use only the wire connectors supplied with Robomow.
Neither Twisted cables, nor a screw terminal insulated with insulation tape
RL555
RL2000
RL855
are a satisfactory splice.
Soil moisture will cause such conductors to oxidize and which later leads to
a broken circuit.
RL555
RL2000
RL855
Only
2.4
Back at Base Station – Completing the Perimeter Wire
Only
setup
Once the Perimeter Wire loop is completed and pegged to the ground, you
complete the setup by attaching the beginning and end of the Perimeter
Wire to the Base Station board.
P Hold both ends of the Perimeter Wire: the wire that started the loop is
the one with an attached connector.
RL555
RL2000
RL855
P Trim the end without the connector to make both of equal length.
Remove any excess wire and Strip back 5 mm (0.2 inches) of insulation
from the wire end.
P Peg the two perimeter wires down to the ground using the same peg
leaving enough loose wire.
Twist together the two loose parts.
P Thread the two twisted wire ends through the center aperture in the
Base Station.
P Insert the end of the wire without the connector into the hole of the other
wire's connector. Use a small flat screwdriver to tighten and secure this
wire into the connector.
RL555
RL855
Only
RL2000
Only
Chapter 2-6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rl855Rl555

Table of Contents